PROline Prowirl 72/73
#
Endress+Hauser
Service adapter
The service adapter is exclusively for connection to Endress+Hauser approved service
interface FXA 193.
Warning!
It is not permissible to connect the service adapter in explosive atmospheres.
Cable entries
Choice of thread for cable entries, M20x1.5 or ½" NPT or G ½" thread (see also the
figures on Pages 2 and 3, number
Cable specifications
The sensor cable connection between sensor and transmitter has an EEx i type of
protection rating (see also the figure on Pages 3; number
The max. capacitance of the cable is 1 µ F/km.
The max. cable inductivity is 1 mH/km.
The cable delivered by E+H (max. 30 m) fulfils these requirements.
Device identification
Transmitter Prowirl 72 and F/W sensor resp. Prowirl 73 and F/W sensor.
Ä
Fig. 2: Nameplate of transmitter and nameplate of sensor (example)
No.
➀
Notified body for QA supervision: TÜV-Hannover/Sachsen-Anhalt e.V.
➁
Place of manufacture
➂
Year of manufacture
➃
Ambient temperature range
➄
Maximum medium temperature
➅
Device group and device category to directive 94/9/EC
➆
Type of protection and explosion group for the measuring system
➇
Applicable Ex documentation
➈
Type code
➃
).
È
Â
ENDRESS+HAUSER
PROWIRL 72
Order Code:
72XXX-XXXXXXXXXXX
EEx d [ia] IIC T6-T1
12345678901
2003
Ser.No.:
KEMA 02ATEX1289 X
ABCDEFGHJKLMNPQRST
TAG No.:
15-36VDC
0.85W
4-20mA, HART
Version:
i
Xa080D/06/../....
0032
II1/2G
T6: -40°C<Ta<+40°C
T5-T1: -40°C<Ta<+60°C
Pat. EP 841 545
Pat. US 4,743,837 US 6,003,384
Å
Ç
À
Ser.No.:
12345678901
Sensor data:
K-factor:
1.0000 P/L
Materials:
CF3M(1.4404) Inconel 718(2.4668)
Gasket:
Graphite
TM:
-200°C...+400°C/-330°F...+750°F
3.1B
Pat. US 4,743,837 US 6,003,384
Meaning
<
➄
).
Á
4153 Reinach
Switzerland
IP67
Æ
Ã
Ta+10°C/18°F
9