Endress+Hauser PROline prowirl 72 Mode D'emploi page 17

Masquer les pouces Voir aussi pour PROline prowirl 72:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

PROline Prowirl 72/73
Endress+Hauser
• Transmitter Prowirl 72:
Prowirl 72***-********A/W
Prowirl 72
The minimum ambient temperature is –40 °C.
Measuring system Prowirl 73 (remote version)
• Sensor:
Prowirl 73***-**4********A/W
Prowirl F/W
at T
= -40 °C ... +40 °C
a
at T
= -40 °C ... +60 °C
a
at T
= -40 °C ... +85 °C
a
The minimum medium temperature is –40 °C.
• Transmitter Prowirl 73:
Prowirl 73***-********A/W
Prowirl 73
The minimum ambient temperature is –40 °C.
Temperature table for use in Zone 21
For devices for use in Zone 21, the ambient temperature-fluid temperature dependency,
indicated in the temperature table for Zone 1 and Zone 0, applies with the following
restrictions in the ambient temperature, however:
–20 °C ≤ T
≤ 55 °C
a
Surface temperature for devices for use in Zone 21
The surface temperature of the device may not exceed 2/3 of the ignition temperature
of a dust cloud. The maximum surface temperature must observe a safety distance of
75 K from the glow temperature of a dust layer of 5 mm.
Example: configuration of the temperature class T4 (135 °C) is suitable for dust with
an ignition temperature of 202.5 °C (1.5 x 135 °C) and a glow temperature of 210 °C
(135 °C + 75 °C).
Approvals
No. / approval type
KEMA 02ATEX1289 X
resp. KEMA 02ATEX1289
EC type-testing certificate according to
directive 94/9/EG (ATEX)
(See Page 7 for notes on special conditions)
Measuring system Prowirl 72, intrinsically safe version EEx i (compact version)
P r o w i r l 7 2 * * * _ * * * * * * . * * * * .
Prowirl 72 F
DN 15...300
Prowirl 72 W
DN 15...150
Max. ambient temperature [°C] in
T6
T5
T4
40
60
60
Max. medium temperature [°C] in
T6
T5
T4
80
95
130
95
130
130
Max. ambient temperature [°C] in
T6
T5
T4
40
60
60
Description
for the electric flow measuring system Prowirl 72 resp. 73
II2G EEx ia IIC T1-T6 resp.
Identification:
II1/2G EEx ia IIC T1-T6 resp.
II1/2GD EEx ia IIC T1-T6
A = 4...20 mA HART, pulse
W = 4...20 mA HART
3 = ATEX II1/2G EEx ia IIC
C = ATEX II2G EEx ia IIC
F = ATEX II1/2GD EEx ia IIC
II2G EEx ia IIC T1-T6 resp.
II1/2G EEx ia IIC T1-T6 resp.
II1/2GD EEx ia IIC T1-T6
II2G EEx ia IIC T1-T6 resp.
II1/2G EEx ia IIC T1-T6 resp.
II1/2GD EEx ia IIC T1-T6
<
T3
T2
T1
60
60
60
T3
T2
T1
195
290
440
195
290
440
195
290
440
T3
T2
T1
60
60
60
5