4
Temperature tables compact version for use in Zone 1
Measuring system Prowirl 72 (compact version)
• Sensor standard temperature version:
Prowirl 72***-**0********A/W
Prowirl F/W
at T
= -40 °C ... +40 °C
a
at T
= -40 °C ... +60 °C
a
The minimum medium temperature is –40 °C.
• High/low temperature sensor version, high pressure version and Dualsens version:
Prowirl 72***-**1********A/W; Prowirl 72***-**2********A/W; Prowirl 72***-**3********A/W
Prowirl F/W
at T
= -40 °C ... +40 °C
a
at T
= -40 °C ... +60 °C
a
The minimum medium temperature is –200 °C.
The following dependency on the ambient temperature applies for fluid temperature < –40 °C:
Medium temperature in °C
Ambient temperature in °C
Measuring system Prowirl 73 (compact version)
• Sensor:
Prowirl 73***-**4********A/W
Prowirl F/W
at T
= -40 °C ... +40 °C
a
at T
= -40 °C ... +60 °C
a
The minimum medium temperature is –40 °C.
Temperature tables remote version for use in Zone 1
Measuring system Prowirl 72 (remote version)
• Sensor standard temperature version:
Prowirl 72***-**0********A/W
Prowirl F/W
at T
= -40 °C ... +40 °C
a
at T
= -40 °C ... +60 °C
a
at T
= -40 °C ... +85 °C
a
The minimum medium temperature is –40 °C.
• High/low temperature sensor version, high pressure version and Dualsens version:
Prowirl 72***-**1********A/W; Prowirl 72***-**2********A/W; Prowirl 72***-**3********A/W
Prowirl F/W
at T
= -40 °C ... +40 °C
a
at T
= -40 °C ... +60 °C
a
at T
= -40 °C ... +85 °C
a
The minimum medium temperature is –200 °C.
The following dependency on the ambient temperature applies for fluid temperature < –40 °C:
Medium temperature in °C
Ambient temperature in °C
Max. medium temperature [°C] in
T6
T5
T4
T3
80
95
130
195
95
130
195
Max. medium temperature [°C] in
T6
T5
T4
T3
80
95
130
195
95
130
195
–40
–80
–120
–40
–35
–30
Max. medium temperature [°C] in
T6
T5
T4
T3
80
95
130
195
95
130
195
Max. medium temperature [°C] in
T6
T5
T4
T3
80
95
130
195
95
130
195
130
195
Max. medium temperature [°C] in
T6
T5
T4
T3
80
95
130
195
95
130
195
130
195
–40
–80
–120
–40
–35
–30
PROline Prowirl 72/73
T2
T1
280
280
280
280
T2
T1
290
440
290
440
–170
–200
–25
–20
T2
T1
290
440
290
440
T2
T1
280
280
280
280
280
280
T2
T1
290
440
290
440
290
440
–170
–200
–25
–20
Endress+Hauser