Clearing Alarm Codes
The alarm condition in the unit must first be corrected. See important note
below. After resolving the alarm condition, press and release the Select key
to remove existing Alarm codes. The Standard Display will appear once the
Alarm codes have been cleared.
T T o o C C l l e e a a r r A A l l a a r r m m C C o o d d e e s s : :
•
Correct the cause of the alarm code.
•
Press the Select key to remove the alarm code.
•
If more than one alarm code is present, press the Select key to clear each
alarm code individually.
I I m m p p o o r r t t a a n n t t : : Continually clearing alarm codes without resolving the problem
will result in damage to the unit and compressor.
R R e e m m a a r r q q u u e e s s : : The bAt alarm is the unique DSR-III alarm that requires manual
confirmation. The DSR-III will keep in OFF condition until the operator
acknowledges and the voltage is above the BCH value(factory setting
10.5v).
T T h h e e w w a a y y t t o o a a c c k k n n o o w w l l e e d d g g e e t t h h i i s s a a l l a a r r m m i i s s a a s s f f o o l l l l o o w w s s : :
1. Press the Select key once to show the Alarm screen. You will now
see the bAt Alarm code.
2. Press the Select key again to acknowledge the alarm, and Press
the select key again and again until the screen returns to the
standard Display.
Visualisation des écrans d'information
Menu principal
À partir de l'affichage standard, utilisez la touche SÉLECTION pour afficher :
1. Alarmes (en cas d'alarmes actives).
2. Dégivrage manuel de l'évaporateur.
3. Température du point de consigne.
Menu Compteur horaire
À partir de l'affichage standard, appuyez sur la touche SÉLECTION pendant
3 secondes pour ouvrir le menu Compteur horaire, puis utilisez la touche
SÉLECTION pour afficher :
1. H H C C : : Nombre d'heures restant avant le rappel d'entretien.