Front edge
Thread on the underside of the tool (battery compartment)
Rear edge
Spike
The PDA 72 measuring extension is screwed into the
underside of the tool.
6.4.3 Angle units
The angle units used to show the inclination can be set to
degrees, percent, mm/m or in/ft. The currently selected
angle unit is shown in a black square.
6.4.4 Expert mode on / off
When the expert mode is active, the timer, min/max
and measuring reference can be combined for use with
all functions. In addition, supplementary information
is shown for the following functions: Area, Volume,
Pythagoras,
Trapezoidal Area,
Distance and Indirect Vertical Distance. If a scale has
been set in the "Settings" menu, this can be shown in
export mode. The choices available are shown at the top
edge of the display.
6.4.5 Changing the favorites bar
All manuals and user guides at all-guides.com
Changes can be made to the favorites bar in these
settings. The favorites bar provides quick access to the
most frequently used functions.
1.
2.
3.
4.
6.4.6 Activating the Scale function
This function allows you to set the desired scale.
1.
2.
3.
6.4.7 Switching the signal tone on / off
The signal tone can be switched on or off in the signal
tone settings.
1.
2.
6.4.8 Permanent laser mode
When in permanent laser mode, a measurement is taken
each time the "Measure" button is pressed. The laser is
not deactivated after the measurement is taken. In this
mode, several measurements can be taken very quickly,
one after the other, with only a few presses of the button.
The corresponding symbol is shown in the status bar of
the main screen.
Indirect Horizontal
6.4.9 Show inclination in the display, on / off
In this menu you can select whether the angle of in-
clination is to be shown in the main screen (activate /
deactivate).
Use the right or left arrow buttons to select the
function you wish to change.
Confirm by pressing the "Measure" button.
Use the right or left arrow button to select the desired
function.
Confirm by pressing the "Measure" button.
Use the left or right arrow buttons to set the desired
scale.
Confirm the applicable number by pressing the
"Measure" button.
Select the "tick" symbol to confirm the value.
NOTE Expert mode must be active in order to be
able to make use of the Scale function.
Use the right or left arrow button to select the desired
setting.
Confirm by pressing the "Measure" button.