5. FIXING THE NICHE IN THE LINER
5.1 In order to fix the niche in a liner
wall you should follow the instructions
given in chapter 2 (place of installation).
Fix the seals (no.19, fig.4), to the niche
(no.21, fig.4) with the screws (no.18,
fig.4), bearing in mind that the liner
will lie between the two seals (no.19,
fig.4). Finally, fit the ring (no.17, fig.4)
and attach it with the screws (no.16,
fig.4).
6. FITTING THE NICHE IN THE LINER
6.1 The niche is supplied with pipes
no.22 and 23 (fig.4) already installed.
Additionally, one of the hoses (no.24,
fig.4) is supplied glued inside pipe
no.22. Once the niche has been fixed to
the wall, following the instructions given
in chapter 2, proceed to install the
pneumatic and air lines.
Installation of the air line:
This line is made up of a hose (no.24),
a flexible pipe (no.25), a male screw
fitting (no.26) and a foot valve (no.27).
All these parts are supplied fitted, so it
is only necessary to glue the end of the
hose (no.24) to the pipe (no.23) which
is already fitted in the niche. It is
important to fix the air line pipe to the
wall of the housing so as to ensure that
the foot valve is in the upper part. This
is so as to avoid sucking up dirt (see fig.
8, page 20).
Lastly, install the flexible pipe (no.15,
fig.4) pressing it inside the nozzle in the
interior of the niche (see fig. 5, page
17).
Installation of the pneumatic line:
This line is made up of a pipe (no.22), a
hose (no.24) and a flexible pipe (no.25).
As the pipe (no.22) and the hose
(no.24) are already installed in the
niche, you only need to glue the pipe
(no.25). Before gluing the end of the
pipe (no.25) to the hose (no.24), fit the
transparent pipe (no.2, fig.3) into the
pneumatic line and pass the end of the
transparent pipe (no.2, fig.3) through
the hole in the niche. Fix it in position
with the clamp (no.20 and 20.1, fig.4).
Once this is complete, glue the pipe
(no.25) to the hose (no.24).
The end of the pipe (no.2, fig.3) will be
connected to the microswitch located
on one side of the hydropneumatic cut
out included with the HIDROJET
equipment.