Télécharger Imprimer la page

GYS TITANIUM 400 AC/DC Mode D'emploi page 32

Masquer les pouces Voir aussi pour TITANIUM 400 AC/DC:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
TIG PROCESS SETTINGS
• The TIG DC is dedicated to the flow of ferrous metals such as steel, stainless steel, but also copper and its alloys and titanium.
• TIG AC is dedicated to the welding of aluminium and its alloys, but also copper.
• The Synergic TIG no longer works on the choice of a DC or AC current type and the settings of welding cycle parameters, but integrates experience-
based welding rules/synergies. This mode therefore restricts the number of settings to three basic settings:
- The type of material.
- The thickness to be welded.
- The welding position.
Settings
Standard
Pulsed
Spot
Tack
Spot Delay
Tack Delay
AC MIX
Type of materials
Diameter of the Tungsten
electrode
Type of priming
Trigger mode
Constant energy welding
TIG DC WELDING
TIG DC - Standard
The TIG DC Standard welding process allows high quality welding on most ferrous materials such as steel, stainless steel, but also copper and its
alloys, titanium... The many possibilities of current and gas management allow you to perfectly control your welding operation, from priming to final
cooling of your welding rod.
Settings
Designation
Pre-gas
Starting current
Starting time
Rising current
Welding current
Downslope
End current
End duration
32
Post-gas
TITANIUM 400 AC/DC
Adjustable
Designation
settings
Smooth current
-
Pulse current
-
Smooth poin-
-
ting
Pulse pointing
-
Repeated
-
smooth pointing
Repeated pul-
-
sed pointing
Mixing current
-
AC and DC
Fe, Al, etc.
1 - 4 mm
HF - LIFT
2T - 4T -
4TLOG
Adjustable
settings
0 - 60 sec.
Time to purge the torch and to protect the area with gas before ignition
10 - 200 %
This starting bearing current is a phase before the current rise ramp.
0 - 10 sec.
0 - 60 sec.
Current rise ramp.
3 - 400 A
Welding current.
0 - 60 sec.
Downslope current.
10 - 200%
This stopping stop current is a phase after the current descent ramp.
0 - 10 sec.
Duration for which gas is released after the arc has stopped. It protects the weld pool
0 - 60 sec.
and the electrode against oxidisation when the metal is cooling down.
TIG
TIG DC
TIG AC
Synergic
-
-
-
-
-
-
-
-
-
-
-
Choice of the material to be welded
Choice of electrode diameter. Allows to refine HF
priming currents and synergies.
Select Starting Function
Choice of trigger welding management mode.
Constant energy welding mode with correction of arc
-
length variations
Description & advice
EN
Recommendations

Publicité

loading