: corresponds to the program reminder modes window:
• JOB: create, save, delete and recall JOB.
4
• QUICKLOAD: JOB trigger recall without welding.
• MULTIJOB : JOB reminder to the trigger in welding.
• Connect-5 (C5): Automatically recall JOBs.
ELECTRODE WELDING (MMA / SMAW)
CONNECTION AND ADVICE
• Connect the cables, electrode holder and ground clamp to the connection connectors.
• Observe the welding polarities and intensities indicated on the electrode boxes.
• Remove the electrode from the electrode holder when the machine is not in use.
• The machine has 3 features exclusive to Inverters:
- The Hot Start creates an overcurrent at the beginning of the welding.
- The Arc Force creates an overcurrent which prevents the electrode from sticking to the weld pool.
- The Anti-Sticking technology makes it easier to unstick the electrode from the metal.
CHOICE OF COATED ELECTRODES
• Rutile electrode: very easy to use in all positions with DC and AC current.
• Basic Electrode: used in all DC and AC positions, it is suitable for safety work due to its increased mechanical properties.
• Cellulosic electrode: very dynamic arc with a high melting rate, its use in all positions makes it especially suitable for pipeline work.
THE SETTINGS OF THE COATED ELECTRODE PROCESS (MMA/SMAW)
Settings
Designation
Electrode type
Anti-Sticking
Choice of polarity
COATED ELECTRODE WELDING (MMA/SMAW)
• MMA Standard
This MMA Standard welding mode is suitable for most applications. It can weld any type of electrode : rutile, basic, cellulosic... and on any material:
steel, stainless steel, cast iron.
TITANIUM 400 AC/DC
Standard
Adjustable settings
(CC)
Rutile
Basic
Cellulosic
OFF - ON
Directe (+=+ et -=-)
Inverse (+=- et -=+)
Pulsed
AC
The electrode type determines specific parameters accor-
ding to the type of electrode used in order to optimize its
weldability.
Anti-gluing is recommended to safely remove the electrode
if it is glued to the part to be welded (the power is automa-
tically cut off).
The replacement of accessories in case of direct or reverse
polarity is carried out at the product level.
EN