4.4
Installing the control unit
WARNING
Disconnect system from energy sources! Make sure that cables and electrical components are disconnected from
the power supply during work.
The control unit can only be opened if the main switch is in the OFF position.
Undo screws in the housing cover and lift up housing cover.
Mount housing in place provided; to do so, use all four fixing options in the corners of the housing.
Take the ambient conditions into account.
4.5
Installing the solenoid valve(s)
Identify supply pipe(s) for refill inlet (d = 1").
Switch off water supply.
Cut through the pipe, cut threads into both sides.
Loosen the screw for the connector plug.
Pull the connector plug off.
Fit the solenoid valve in the pipe, check for a tight fit.
Fit the connector plug again analogue to its removal.
The solenoid valves are normally closed.