5. Installation
Evaluation of
digital signals
Evaluation of
an analogue
signal
Use of the re-
lay
Using the
open drain
outputs
5 Installation
36 / 176
Changes in the voltage level are detected as a signal.
You can evaluate signals between 0 V
Signals from 0 V
whereas signals from +2.0 V
as High . You can respond to signals and trigger actions
in the LSM.
The RouterNode 2 digitises the voltage level and
compares the values with a threshold value. You can
configure this threshold value in the WaveNet Manager
and trigger an analogue event. In LSM event
management, you specify how the system is to
respond to the occurrence of this event.
The relay offers two potential-free outputs and a
common earth connection. You can use the relay to
control external devices.
In the switched state, the open drain outputs establish
an electrical connection to the ground potential of
RouterNode 2.
The device can be fitted horizontally or vertically. You
can fit it in a horizontal position easily and safely using
the integrated mounting holes. Take into account the
internal antenna's directional characteristic (see
Antenna) and align the device as appropriate.
RouterNode 2, GatewayNode 2,
are detected as Low ,
to +0.8 V
DC
DC
to +3.3 V
DC
SmartBridge
and +3.3 V
.
DC
DC
are detected
DC
EN