FILTER CARTRIDGE REPLACEMENT

NOTE: The life of the filter cartridges depends on water
volume used and the quality of the feed water. It is
recommended that the filter cartridges be replaced
every 6-12 months, or when there is a noticeable
change in taste, odor, or flow of filtered water.
Ensure the correct cartridges are purchased for
the system.
Model F3000-B2B and F3000-B2M use F2B2-RC2 Replacement
Cartridge set and F1S5-RC Cartridge.
8. Cartridge Replacement
A. Relieve pressure by turning off the water supply to the
system and opening a faucet until water flow stops. Place a
bucket or towel under the system to catch any water drips
(Figure 8a).
B. Remove the cover and lift the locking bar upward until the
filter cartridge disengages from the filter head assembly
(Figure 8b).
C. Pull the cartridge away from the filter head assembly
(Figure 8c).
D. Ensure the locking bar is fully in the up position (Figure 8c).
E. Align the posts on the filter cartridge with the ports in the
filter head assembly. Slide the cartridge filter towards into
the filter head assembly engaging with the locking bar
causing it to drop forward and down. (Figure 8d).
F. Pull down the locking bar until it snaps into place
(Figure 8e).
G. Install cover.
NOTE: See Placing the System into Operation section for
remaining steps.
TROUBLESHOOTING
Leaks between filter head assembly and filter
cartridge
1. Relieve pressure by turning off the water supply to the
system and opening faucet until water flow stops. Place a
bucket or towel under the system to catch any water drips.
2. Remove cartridge and inspect O-rings to make sure they
are seated and clean.
3. Install filter cartridge. Place system into operation and
check for leaks. If leaks persist, turn off the water supply
and contact Technical Support at 1-800-279-9404.
Leaks from tubing fittings
1. Relieve pressure by turning off the water supply to the
system and opening faucet until water flow stops. Place a
bucket or towel under the system to catch any water drips.
2. Depress collet on system or inlet supply adapter tubing
fittings and pull tubing from fitting. Inspect surface of
tubing for scratches or debris. Clean or cut back tubing to
access clean surface.
3. Wet the end of the inlet tubing and press into the inlet
fitting of the system. Ensure the tubing is fully pushed past
the fitting O-rings. Place system into operation and check
for leaks. If leaks persist, turn off the water supply and
contact Technical Support at 1-800-279-9404.
8a
Inlet
(white tubing)
8b
8d
F3000-B2B, F3000-B2M Filtration Systems Instruction Manual • 7
Outlet (blue tubing)
8c
8e