Filter Cartridge Replacement - Pentair OMNIFILTER BF6 Instructions D'installation

Boîtier de filtration de l 'eau lourde
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

FILTER CARTRIDGE REPLACEMENT

1. Place a pan under the unit to catch any spilled water. Turn off water supply
to filter. Depress red pressure-relief button on top of filter. Use housing
wrench to unscrew bottom of housing. Turn slowly to the left and support
the housing and piping as you loosen the housing.
NOTE: If turning off water supply to the filter will also turn off water supply
to the rest of the home, be sure to fill a bucket of water first to allow you to
clean the housing after it has been removed.
2. Pour out the water from the housing and remove and discard the old
cartridge. Locate and remove large O-ring, wipe clean of lubricant and set
aside. Rinse out bottom of housing and fill about 1/3 full with water. Add
about 2 tablespoons of bleach and scrub cap and bottom of housing with
nonabrasive sponge or cloth. Rinse thoroughly. Check O-ring for damage.
If cut, scratched, or stretched, replace it with a new one. If the O-ring is
in good condition, lubricate it with clean silicone grease, insert it back
into groove and smooth into place with finger. Insert new cartridge over
standpipe in bottom of housing.
3. Screw bottom of housing onto the cap and hand-tighten.
DO NOT OVER-TIGHTEN. Turn on water supply slowly to allow filter to fill
with water. Depress red pressure-relief button to release trapped air.
Check for leaks before leaving installation.
NOTE: After installation, flush the cartridge for 10 minutes, wait one hour,
then flush again for 10 minutes before using the water.
NOTE: Use only genuine OMNIFILTER replacement cartridges for best
results. Failure to use OMNIFILTER replacement cartridges will void
your warranty.
TROUBLESHOOTING
Leaks between cap and bottom of filter housing:
1. Turn off water supply and depress pressure-relief button.
2. Clean and lubricate O-ring with silicone grease. Also, clean the groove
where the O-ring seats with a clean cloth. Replace O-ring back in groove
above threads. Screw bottom of housing back on cap securely by hand.
DO NOT OVER-TIGHTEN.
3. Turn on water supply. If leaks persist, or if there are other leaks on the
system, turn off water supply. Call OMNIFILTER Customer Service at
800.279.9404.
Leaks on inlet/outlet connections:
1. Turn off water supply. For brass fittings, tighten nut 1/2-turn
with wrench.
2. Turn on water supply. If leaks persist, or if there are other leaks on system,
turn off water supply. Call OMNIFILTER Customer Service at 800.279.9404
MAINTENANCE
Contact your local area retailer for replacement cartridge pricing.
The BF6 is covered by a limited 5 year warranty. See warranty
for details.