Design And Function - WIKA TR36 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

2. Design and function

2. Design and function
2.1 Overview
Angular connector DIN EN 175301-803 form A
Process connection
Probe tube
2.2 Description
The model TR36 resistance thermometer consists of a thermowell/
protection tube with a fixed process connection and is screwed directly
into the process.
If the resistance thermometer is to be operated in an additional
protection tube, a spring-loaded compression fitting must be used.
They are designed to be resistant to shock and vibration and all electrical
components are protected against splash water. The vibration resistance
conforms to IEC 60751 (8 g, dependent on the instrument version). The
impact resistance of all versions meets the requirements of IEC 60751.
WIKA operating instructions model TR36
EN
5

Publicité

Table des Matières
loading

Table des Matières