7. Configuration software WIKAsoft-TT
7.3 Fault diagnosis
Here, in the event of an "error detected by the transmitter", the error
message is displayed.
Examples: Sensor break, permitted highest temperature exceeded, etc.
EN
In normal operation, "No fault - No maintenance requirement" is
displayed here.
7.4 Measured values
Line recorder - Here the measured value progression is represented in
the format of a chart recorder with a constant sampling rate in a defined
time interval (180 seconds) and a variable temperature axis.
The display purely serves as a functional check and for information.
An export of the data is not possible.
7.5 Configuring several instruments identically
First instrument
■
1. "Loading configuration"
2. [optional] Cancel write protection ("key" symbol at the bottom
right)
3. Change the required parameters
4. "Save to the instrument"
5. [optional] Activate write protection
All following instruments
■
1. "Loading instrument data"
2. [optional] Cancel write protection
3. [optional] Change the required parameters, e.g. tag number
4. "Save to the instrument"
5. [optional] Activate write protection
20
WIKA operating instructions model TR36