Cable Type - CAME GGT40AGS Manuel D'installation

Masquer les pouces Voir aussi pour GGT40AGS:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Maximum capacity of contacts
The total power of the outputs listed below must not exceed the maximum output power [Accessories]
Device
Accessories
Additional light
Flashing beacon
Operator status warning light
RGB LED strip
Electric lock
BUS*
The outputs deliver 24 V DC when the batteries start operating, if they are installed.
(*) Only connect CAME devices with CXN BUS system
Devices with BUS CXN system
The CXN CAME system is a two-wire non-polarised communication BUS which allows you to connect up all compatible CAME devices.
Connection to the BUS can be in a chain, star or mixed formation.
Once the system has been wired, and after having set the address on each device, the function of each accessory can be configured on the control panel. This
method allows you to configure the set-up immediately without having to do so later and intervene directly on the accessories and system wiring.
The CXN BUS can support control devices, photocells, safety devices, beacons and gateways at the same time.
Cabling
1
Chain connection
2
Star connection
3
Mixed connection

Cable type

We recommend using a FROR 2x1mm² cable, maximum length from the control board: 50 m.
Single branch length (m)
BUS cable
The total length of all branches can be a maximum of 150 m.
The cable cannot be shielded.
Maximum number of devices that can be connected, by type
Type of device
Selectors
Photocell pairs
Flashing beacons
Output
10 - 11
10 - E1
10 - E1
10 - 5
+RG
Eb- - Eb+
BUS
Power supply (V)
24 AC
24 AC
24 AC
24 AC
24 DC
24 DC
15 DC
max. 50 m
2 x 1 mm²
Maximum number of devices per type
7
8
2
Power (W)
40
15
15
3
12
5
15

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ggt40rgsGgt40rx4Ggt40ax4Ggt40ax6Ggt40acs