CAME GGT40AGS Manuel D'installation page 67

Masquer les pouces Voir aussi pour GGT40AGS:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Pre-flashing time
Set the time for which the beacon is activated before each manoeuvre.
F21
Courtesy time
Set the lighting device operation time.
F25
Opening speed
Set the opening speed as a percentage.
For booms complete with accessories (swing rest and/or skirt), reduce the speed.
F28
Closing speed
Set the closing speed (percentage of maximum speed).
For booms complete with accessories (swing rest and/or skirt), reduce the speed.
F29
Travel sensitivity
Adjust the obstruction detection sensitivity during boom travel.
F34
RSE
Configure the connector connections on RSE1 and RSE2.
If an RSE card – configured for paired connections – is plugged into the RSE_1 connector, use the RSE_2 connector for remote connection (CRP). In this
case, a CAME KEY cannot be connected.
F49
Save data
Save user data, timings and configurations to a memory device (memory roll or USB key).
The function is displayed only when a USB stick is inserted into the USB port or a memory roll card is inserted into the control board.
F50
Read data
Load user data, timings and configurations from a memory device (memory roll or USB key).
The function is displayed only when a USB stick is inserted into the USB port or a memory roll card is inserted into the control board.
F51
OFF (Default)
1 to 10 seconds
60 to 180 seconds (Default 180 seconds)
50% to 100% (Default 70%)
from 30% to 100% (Default 50%)
10% to 100% (Default 100%)
10% = minimum thrust and high obstruction sensitivity
100 % =maximum thrust and low obstruction sensitivity
rE1
1 = Paired
3 = CRP/CAME KEY (Default)
4 = Alternate
OFF (Default)
ON (Run operation)
OFF (Default)
ON (Run operation)
rE2
3 = CRP/CAME KEY (Default)
5 = I/O - RS485
6 = ModBus

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ggt40rgsGgt40rx4Ggt40ax4Ggt40ax6Ggt40acs

Table des Matières