11 Instructions for normal
operation
Do not use the wiper if the outside
temperature is below 0°C or in case of ice.
If it is left on, the wiper automatically
disables itself.
The device control can be performed through
different modes.
• Through the user's controls of the web interface (
9.2 Web interface, page 16).
• Through Video Management Software (VMS)
that supports the ONVIF protocol. In this case
the Special controls are implemented using the
auxiliary commands of the ONVIF protocol.
• Through PTZ Assistant software (refer to the
manual of the product).

12 Maintenance

CAUTION! Device installation and
maintaining must be performed by
specialist technical staff only.

12.1 Fuses replacement

CAUTION! For continued protection against
risk of fire, replace only with same type and
rating of fuse. Fuses must be replaced only
by service personnel.
If necessary, the connector board's fuses can be
replaced (7.3.1 Connector board description, page
12). The new fuses must comply with the directions
given in the table.
FUSES REPLACEMENT
Voltage
Fuse FUS1
24Vac, 50/60Hz
T 4A L 250V 5x20
120Vac, 50/60Hz
T 4A L 250V 5x20
230Vac, 50/60Hz
T 4A L 250V 5x20
Tab. 6
As an alternative, use approved fuses featuring the
same characteristics.
18

12.2 Factory Default

It is possible to reset to the factory default settings.
The effect of the Factory Default procedure is the
same obtained through the web interface (Hard Reset
button, Web Interface manual, Tools Page).
To carry out the factory default procedure it is
necessary to access the dip-switches via the
configuration door.
Follow the procedure below:
• Disconnect the power supply to the unit.
• Open the configuration door.
Fig. 22
• Set all DIP 3 dip-switches to ON.
Fig. 23
• Power the unit. Wait for 2 minutes.
• Disconnect the power supply to the unit.
Fuse FUS2
T 6.3A H 250V 5x20
T 4A H 250V 5x20
T 2A H 250V 5x20
DIP3
DIP2
DIP1
MNVCUCHDB_2104_EN