Prothermo NMT81
Réglage usine
Expert settings?
Navigation
Description
Sélection
Distance tank level uncovered
Navigation
Description
Entrée
Réglage usine
Distance tank level covered
Navigation
Description
Entrée
Réglage usine
Distance water level uncovered
Navigation
Description
Entrée
Endress+Hauser
0 m
Guide utilisat. → Mise en service → Expert settings?
By activating this option you will be asked to
a) adjust the default values for covered/uncovered elements.
b) change the element weighting depending on your tank shape.
Oui
Guide utilisat. → Mise en service → Level uncovered
Used this function to define the distance, an element has to be uncovered, before included
in vapor average temperature calulation.
0 ... 1 m
50 mm
Guide utilisat. → Mise en service → level covered
Used this function to define the distance, an element has to be covered, before included in
product and liquid average temperature calculation.
0 ... 1 m
50 mm
Guide utilisat. → Mise en service → wt lvl uncovered
Used this function to define the distance, an element has to be above the water level,
before it is included in average product temperature.
0 ... 1 m
Description des paramètres de l' a ppareil
19