SSS Siedle ZAM 600-01 Mode D'emploi page 8

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 10
English
Application
Status display module with visual
and acoustic feedback.
Four backlit LED symbols signal
the different statuses: "Call",
"Not available", "Speech" and
"Door release".
The optical signal can be optically
supported by an acoustic feedback.
Electrical voltage
Mounting, installation and servicing
work on electrical devices may only
be performed by a suitably qualified
electrician.
Servicing
Information on module changing is
provided in the Vario door station
installation instructions.
1/2 Optical and acoustic
signalling
1 Call
2 User unattainable
3 Door opened
4 Speech
8
ZAM 600-...
for Siedle In-Home bus or
Siedle Multi
Scope of supply
• ZAM 600-...
• Ribbon cable for BTLM 651-... for
actuating the ZAM 600-...
• Terminal block
• This product information
Terminal assignment ZAM 600-...
b+
Supply 12 V AC,
c-
15–32 V DC
BU
Control input transducer
S1
Control input for "call"
status display
S2
Control input for "speech"
status display
S3
Control input for
"door opened"
status display
S4
Control input for
"cannot be reached"
status display
L01
RF output
L02
H/L
Impedance high/low
Note
As this is used in different systems,
not all the terminal connections are
always required. For details, see the
wiring diagrams.
Terminal plans
3 a+b In conjunction with the
In-Home bus, actuation takes place
via a ribbon cable from BTLM 651-...
or BTLM 650-04 ES7007.
4 In conjunction with the Multi
system, actuation takes place via a
SCM 640-...
Activating the acoustic feedback
On the back of the ZAM 600-... is
a DIL switch which can be used to
activate the acoustic feedback for
the status messages.
Connection of an external induc­
tion loop system or AF amplifier
(only In-Home bus)
Audio OUT: The AF output signal is
applied to terminals L01, L02.
The output impedance is 10 kOhm.
By inserting a bridge from L01 to
H/L, the output impedance is set
from 10 kOhm to 600 Ohm – in
accordance with a 0 dB interface.
5 To output the NF signal, the ribbon
cable from the BTLM 651-... or
BTLM 650-04 ES7007 must be con-
nected to the ZAM 600-...
For the ZAM 600-..., the NF output
level also depends on the volume
setting of the BTLM 651-... or
BTLM 650-04 ES7007.
Specifications ZAM 600-...
Output impedance NF signal:
10 kOhm, with bridge 600 Ohm
Operating voltage: 12 V AC,
15–32 V DC
Operating current: 70 mA
Protection system: IP 54
Ambient temperature:
–20 °C to +55 °C
Dimensions (mm) W x H x D:
99 x 99 x 26
Inputs (BU, S1, S2, S3, S4):
12 V AC, 15–32 V DC

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Zam 670-0

Table des Matières