Technical Manual
Absolute Single/Multiturn Profibus Encoders
6. Value for Total Resolution
Example: Value for total resolution 36000
Position range: 0...36000
Revolutions 10
If the scaling values (TMR/MUR) cannot be divided without a rest there will be an error at the limits of the
position values ( value < 0 and < maximum position). This can be avoid with a multiple value of MUR to TMR.
1
3
D
e
f
a
u
l
t
s
e
t
t
i
n
g
1
3
D
e
f
a
u
l
t
s
e
t
t
i
n
g
On delivery the following parameters have been factory set.
Description
Setting
Baud rate
automatic
Node address
125
Termination
OFF
Index (hex)
Set_prm 9
Set_prm 10‐13
Set_prm 14‐17
If errors have occurred during programming of the objects and if these parameters have been saved in the
EEPROM, it will not be possible to address the encoder next time it is switched on; this error can be cleared only
by means of a general Reset of the encoder.
R.000.000
s
o
n
d
e
l
i
v
e
r
y
s
o
n
d
e
l
i
v
e
r
y
Switch
Not available
*At closed housings the switch is set to the preorded node address or
to 0xFF for "set station address" with software
Switch setting off
Name
Encoder Profile
Operating Parameter
Measuring Units per Revolution
Total Measuring Range
Standard value
Bit 3 Scaling on
Class 2 on /CW
8192 (13 Bit)
33554432 (25 Bit)
13-16 of 16