With Standard Scaling, scaling will be done as follows: 
 
o With MUR and TMR 
o One revolution is equivalent exactly to MUR  = TMR values 
 
Position
 = ((Position
scaled
 
 
With Alternative Scaling, scaling will be done as follows: 
 
o With NDR and TMR 
o NDR revolutions are equivalent exactly to the TMR values 
 
Position
 = ((Position
scaled
 
 
1. Code sequence  CW 
 
Possible settings: 
Increasing clockwise (0)  (CW) 
Increasing counter‐clockwise (1) (CCW) 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
2. Class 2 functionality on 
 
Class 2 must be turned on when scaling is active.  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
R.000.000
 
 / Singleturn‐resolution) * MUR) % TMR 
unscaled
 / (NDR * Singleturn‐resolution)) * TMR) % TMR 
unscaled
12-14 of 16