Power Supply; Pulse Output - INTEGRA Metering AMFLO SONIC Smart Instructions De Montage Et Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

3.3.2. Power supply

NOTICE
The voltage range needs to be adhered to.
Pin: 1 and 3
4 - 24 VDC (max. power 10 mA) complies at least with EN 1434.

3.3.3. Pulse output

Pin: 2 and 4
Mode: passive (solid state relais)
Max. power/max. voltage: 50 mA / 48 V
Max. output frequency: 200 Hz
Nominal diameter
DN
Pulse value
3.4 Schutz vor Manipulation
NOTICE
At delivery AMFLO
nipulation.
However, with the detachable standard cable there is the possibility that the user
might interrupts the connection and thus no data can be transmitted. If this can-
not be excluded we recommend the use of the delivered protective cover. The
protective cover encloses the plug connection and can be secured with a wire
seal at this point.
Danger of manipulation by end consumers!
• After successful installation of AMFLO
cover is placed over the electrical unit and the plug connection.
• Guide the wire seal through the two holes in the protective cover.
• Pull the seal as tight as possible to the protective cover and seal it.
mm
20
Zoll
½
litre/pulse
0.1
®
SONIC Smart is protected with a factory seal against ma-
25
32
¾
1
0.1
0.1
®
SONIC Smart the protective
40
0.1
27

Publicité

Table des Matières
loading