Electrical Installation; Power Supply - INTEGRA Metering AMFLO MAG Smart Instructions De Montage Et Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Electrical installation

Power supply

24 VDC ±10 % (max. current 150 mA).
The power supply must be galvanically isolated. Furthermore the specified voltage deviations of ±10 % must not be
exceeded.
Wiring
The AMFLO
®
MAG Smart flow sensor is connected to a heat or flow meter as follows:
Wire colour:
Function:
yellow
pulse output
pink
status output
green
pulse/status output Common
brown
24 VDC (supply)
blue
GND (supply)
Because of possible water condensation on the device, the system cable head must be positioned to point downwards. With the rest of the
cable leading upwards, condensation flowing to the heat meter is avoided.
Correct installation for horizontal mounting:
DN 15...25
top
bottom
Pulse output:
Mode:
Max. current/max. voltage:
Max. output frequency:
Nominal diameter DN
mm
inches
Pulse value
ml
14
DN 32...100
Flow direction
passive (solid state relais)
50 mA, 48 V
200 Hz
15
20
25
32
1/2
3/4
1
1 1/4
5
10
15
25
top
Flow direction
bottom
40
50
65
80
1 1/2
2
2 1/2
3
35
50
85
130
100
4
200
AMFLO
®
MAG Smart

Publicité

Table des Matières
loading