16. Risk Analysis
In accordance with EN 12100. See Attachment:
17. Maintenance, Transport and Storage
Inspection and maintenance work on all parts of the UNIDRIVE must only be carried out by the
manufacturer's personnel or by persons authorized by him in writing.
Exclusively, only original Mittelmann spare parts must be used.
The equipment must be inspected and serviced every 12 months by the manufacturer or by per-
sons authorized by him in writing.
All maintenance and repair work must be recorded in the inspection log book of the operating
company.
Heavy soiling and wear of the lifting gear can adversely affect the functioning of the equipment.
Therefore, for reasons of safety, the lifting gear must be replaced as and when required, after
1,000 m downwards travel (see the Log Book) or at the latest after 4 years. Exclusively only lifting
gear specified by the manufacturer must be used. Replacements must only be carried out by the
manufacturer or by persons authorized by him in writing.
The manufacturer accepts no liability whatsoever for damage or injury resulting from incorrect and
/ or improper service and / or repair work carried out by third parties.
Corrosion resistance when used in the open air is to a large extent ensured not only by the selec-
tion of the appropriate materials but also by protective surface coatings, whereby this must be
supported by the appropriate regular maintenance.
Emissions emitted by this machine are sound pressure values only which lie below 75 dB(A).
Appropriate special precautions must be taken for the transport and storage of the UNIDRIVE. For
this a suitable transport and storage box should be used. In every case here, the operating in-
structions of the additional personal protective equipment against falling must be complied with.
18. Important Information
18.1 Testing and Approval of the Device
The UNIDRIVE complies with the Machinery Directive 2006/42/EC and its components are type-tested
Category III personal protective equipment products against falls. They are subject to monitoring by
Page 34