Original Operating Instructions UNIDRIVE
0158
3.
Operation
The operating instructions of the products which are to be used with the UNIDRIVE, (for example, full
body harness or rescue harness) are also applicable independently of these operating instructions.
The important parts, especially the function of the individual products can be found in them in detail.
3.1
Selection of the Anchor Point
To use the UNIDRIVE, anchor points each with a minimum load-bearing capacity of 10 kN are re-
quired (EU regulation). When being used outside the EU, the country-specific requirements for the
strength of the anchor points are applicable.
3.2
Anchoring the UNIDRIVE
The UNIDRIVE is fixed to the anchor point. In doing so, it must be ensured that no knots or kinks are
formed in the lifting gear. The lifting gear must hang straight and free, otherwise and the use of the
UNIDRIVE without risk is not possible.
The anchoring of the UNIDRIVE must not be carried out in areas where there is the danger of falling.
As soon as the activity has to be carried out at an edge fall point, a fall arrest system in accordance
with EN 363, consisting of a full body harness in accordance with EN 361, fasteners, lanyards etc. in
accordance with EN 354 and a fall damping component in accordance with EN 355 must be used.
Symbol for information that the operating instructions must be
complied with
CE-Mark and Identification Number of the notified body involved
in the control of PPE:
DEKRA EXAM GmbH
Dinnendahlstraße 9
44809 Bochum
Page 11