4.1.2. Safety distances

See figure 6.
A.
Ceiling. The minimum safety distance between
the stove and the ceiling is 1200 mm.
B.
Masonry walls. Leave 50 mm between the
stove and walls, provided that the air can
circulate in front and to one side of the stove.
If the stove is installed in a recessed wall, leave
100 mm between the stove and walls for the
air circulation.
C.
Walls and benches made of inflammable
materials. The minimum safety distances to
inflammable materials: 500 mm on either side
and behind the stove, 500 mm in the front.
d.
Space required for use and maintenance. The
stove user needs at least one square metre of
space in front of the stove.
min.
50
B
D
A
C
min.
500
Figure 6. Safety distances (all dimensions in millimeters)
Figure 6. Distances de sécurité (toutes les dimensions sont fournies en millimètres)
4.1.2. distances de sécurité
Voir figure 6.
A.
B.
C.
d.
min.
min.
100
100
B
D
min.
50
FR
Toit : la distance de sécurité minimale entre le
poêle et le toit est de 1 200 mm.
Murs maçonnés : laissez 50 mm entre le poêle
et les murs, à condition que l'air puisse circuler
à l'avant et sur un côté du poêle. Si le poêle
est encastré dans un mur, laissez 100 mm
entre le poêle et les parois afin de permettre à
l'air de circuler.
Murs et plates-formes en bois : les distances de
sécurité minimales par rapport aux matériaux
inflammables sont de 500 mm d'un des côtés
du poêle et à l'arrière, et de 500 mm à l'avant.
Espace requis pour l'utilisation et l'entretien :
l'utilisateur doit disposer d'au moins 1 m² d'es-
pace libre devant le poêle.
C
min.
500
C
min.
500
min.
500
D
C