Relai De Signalisation De Défaut K1; Commentaire Reglage Par Defaut - Chauvin Arnoux PYRO CONTROLE THYRITOP 300 Notice De Fonctionnement

Régulateur de puissance
Table des Matières

Publicité

DESCRIPTION
D'ERREUR
DEFAUT MATERIEL
FREQUENCE MINIMALE
FREQUENCE
MAXIMALE
TOLERANCE DE
FREQUENCE
ADMISSIBLE
ROTATION DES
PHASES ANTIHORAIRE
PHASE L1 MANQUANTE
PHASE L2 MANQUANTE
PHASE L3 MANQUANTE
ERREUR DE
CONSIGNE (<4mA)
PAS D'ALIMENTATION
ELECTRIQUE
RACCORDEMENT
BLOC D'ALIMENTATION
ERREUR DE CAPTEUR
DE TEMPERATURE
DEFAUT FUSIBLE
COURT CIRCUIT DU
THYRISTOR
DEFAUT EEPROM
DEFAUT I2C
DEFAUT ETHERNET
DEFAUT USB
DEFAUT FIRMWARE
DEPASSEMENT DE
GAMME DE MESURE U
DEPASSEMENT DE
GAMME DE MESURE I
PUISSANCE NEGATIVE
DEFAUT LCD
ERREUR DE
PARAMETRE
MIN USECTEUR
MAX USECTEUR
MIN UCHARGE
MAX UCHARGE
MIN ICHARGE
MAX ICHARGE
MIN PCHARGE
MAX PCHARGE
MIN RCHARGE
MAX RCHARGE
MAX IPIC
TEMP MIN
DISSIPATEUR
TEMP MAX
DISSIPATEUR
Les événements qui sont enregistrés par le Thyritop 300, sont affichés sur l'interface tactile de façon
abrégée sous forme de liste. Ces événements correspondent contextuellement à leurs formes
complètes et peuvent être identifiées en se référant au tableau ci-dessus.
6.8.2
RELAI DE SIGNALISATION DE DEFAUT K1
COMMENTAIRE
REGLAGE PAR DEFAUT
Le relai de signalisation K1 fonctionne sur le principe d'un circuit fermé par défaut.
Ce réglage peut être modifié avec la console de commande, avec le module bus, ou
avec le Thyritop-Tool 300.
TEXTE THYRITOP
MESSAGE
TOOL 300
AFFICHAGE
HARDWARE FAULT
HW FAULT
FREQUENCY TOO
FMIN
LOW
FREQUENCY TOO
FMAX
HIGH
FREQUENCY
FTOLERANCE
TOLERANCE
NO ROTATING
NO ROTFIELD
FIELD
PHASE L1 MISSING
NO PHASE1
PHASE L2 MISSING
NO PHASE2
PHASE L3 MISSING
NO PHASE3
SETPOINT < 4MA
SETPOINT
(OPEN LOOP)
NO SUPPLY
NO POWER
VOLTAGE
POWER UNIT
NOCONNPART
DISCONNECTED
TEMPERATURE
TEMPSENS
PROBE DEFECT
OPEN FUSE
FUSE
THYRISTOR SHORT
THYRISTOR
CIRCUIT
MEMORY ERROR
EEPROM
2C ERROR
I2C
ETHERNET ERROR
ETH
USB ERROR
USB
FIRMWARE ERROR
FIRMWARE
POWER UNIT
INCOMPATIBLE
U MEASURING
U RANGE
RANGE EXCEEDED
I MEASURING
I RANGE
RANGE EXCEEDED
NEGATIVE POWER
NEG POWER
LCD ERROR
LCD
PARAMETER
PARAMETER
ERROR
U MAINS < MIN
UN MIN
U MAINS > MAX
UN MAX
U < MINIMUM
UL MIN
U > MAXIMUM
UL MAX
I < MINIMUM
IL MIN
I > MAXIMUM
IL MAX
P < MINIMUM
PL MIN
P > MAXIMUM
PL MAX
R < MINIMUM
RL MIN
R > MAXIMUM
RL MAX
I PEAK > MAXIMUM
I_PEAK MAX
TEMPERATURE
T_HEAT MIN
HEAT SINK < MIN
TEMPERATURE
T_HEAT MAX
HEAT SINK > MAX
Tab. 4 : Liste des événements, erreurs ou états
AFFICHAGE
RELAI
ROUGE
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
35
INHIBITION
DATA
D'IMPULSIONS
LOGGER
NON CONFIG.
X
NON CONFIG.
X
NON CONFIG.
X
NON CONFIG.
X
NON CONFIG.
X
NON CONFIG.
X
NON CONFIG.
X
NON CONFIG.
X
X
X
NON CONFIG.
X
NON CONFIG.
X
X
NON CONFIG.
X
X
X
X
X
X
NON CONFIG.
X
X
X
X
X
NON CONFIG.
X
X
X
X
X
X
X
X
X
X
X
X
X