GB
pRobLEM
B. Plunger is difficult to
pull/push
C. The fill tube will not
fill with paint or paint
leaks from fill valve
Locking cap
Retaining disk
Duckbill valve
Item
description
1,3
Roller core and cap*
2
Roller cover 12 mm
Roller cover 20 mm (accessories)
Roller cover 20 mm, padded (accessories)
4,5,6
Seal, roller arm and O-ring*
4,6
Seal and O-ring
7
O-ring
8,9,10
Locking cap, retainer disk, duckbill valve*
11,12
Suction system*
* denotes parts that can only be purchased together and not individually.
8
All manuals and user guides at all-guides.com
cAuSE
1)
O-rings are not lubricated
1)
Paint residue on fill valve
components
1)
turning counterclockwise.
2)
the valve housing
3)
cleaning solution
Valve housing
4)
Connecting
5)
area
turning it counterclockwise.
parts List (fig. 19)
Unscrew the locking cap on the valve housing by
Remove the retaining disk and the duckbill from
Clean these parts thoroughly using the appropriate
Replace the duckbill valve and retainer disk.
Screw the locking cap on the valve housing by
HandiRoller 550
SoLuTIoN
1)
Lubricate the O-rings on
the plunger
1)
Insert fill tube firmly into
fill valve and twist fill tube
several times to break up
paint residue.
2)
If the problem persists,
refer to the steps below
to clean the fill valve
components.
part No.
2325720
2325718
2325719
0220324
2325740
2325742
2326966
2325721
2325746
Qty.
1
1
1
1
1
1
2
1
1