ALTERNATE CONNECTION
Important! First do the following on both operators:
- insert the RSE card (with the dipswitches set to OFF) on the panel connector on both operators.
- connect the two boards with a CAT 5 cable (max. 1,000 m) to terminals A-A / B-B / GND-GND; see CONNECTION FOR PAIRED OR ALTERNATE
OPERATION)
Connect the safety and control devices with the OPEN function (contact 2-3) and STEP-BY-STEP (contact 2-7) on the panel on the MASTER operator.
Connect the safety and control devices with the PARTIAL/PEDESTRIAN OPENING function (contact 2-3P) on the panel of the SLAVE operator only.
Important! Activate the F 19 function (automatic closing time) on the panel on both operators.
Saving
Follow the procedure for entering a user with the OPEN and STEP-BY-STEP command on the MASTER panel and the PARTIAL/PEDESTRIAN OPENING
on the SLAVE panel.
Confi guring the MASTER operator
Select function F 49. Press ENTER to confi rm.
Select 2 (alternate) and press ENTER.
Parameter transfer from MASTER to SLAVE
Select function F 52 on the MASTER panel.
Select 1 and press ENTER.
Programming
Set the following functions on both barriers:
- motor type (A1);
- motor test (A2);
- total stop (F1);
- travel calibration (A3).
Proceed with setting and adjusting the MASTER panel.
Function modes
OPEN command (contact 2-3). To open the MASTER barrier boom.
PARTIAL/PEDESTRIAN OPENING command (contact 2-3P). To open the SLAVE barrier boom.
STEP-BY-STEP command (contact 2-7). Both booms open. This is an emergency opening command to free up the passage.
For information on the types of command that can be selected and associated with users, see the section ENTERING USERS WITH AN
ASSOCIATED COMMAND.
Send an OPEN command (contact 2-3)
from the transmitter or other control device
to open the MASTER barrier boom.
SLAVE
MASTER
Approach the SLAVE barrier which will open
automatically only after the MASTER barrier
has closed automatically.
SLAVE
MASTER
Send a PARTIAL/PEDESTRIAN OPENING
command (contact 2-3P) from the
transmitter or other control device to open
the SLAVE barrier boom.
SLAVE
MASTER
Approach the MASTER barrier which will
open automatically only after the SLAVE
barrier has closed automatically.
SLAVE
MASTER
SLAVE
MASTER
Send a STEP-BY-STEP command (contact
2-7) from the transmitter or other control
device to open the MASTER and SLAVE
barrier booms at the same time.
SLAVE
MASTER