F31 Closing slow-down
speed
Setting the boom closing slow-down speed, calculated as a percentage.
⚠ Warning: the speed parameter fi elds vary according to the type of boom:
- for 2 m booms with a joint, set the slow-down speed percentage from 20 to 40;
- for 4 m booms, set the slow-down speed percentage from 20 to 30.
- for 6 m booms, set the slow-down speed percentage from 15 to 30;
- for 8 m booms, set the slow-down speed percentage from 15 to 20.
F33 Calibration speed
Setting the boom travel automatic-calibration speed, calculated as a percentage.
F34 Travel sensitivity
Adjusting obstruction detection sensitivity during travel.
F35 Slow-down sensitivity
Adjusting obstruction detection sensitivity during slow-down.
F37 Opening slow-down
point
Adjusting the starting point of opening slow-down for the boom as a percentage of the total travel.
Warning! The percentage varies depending on the type of boom:
- for booms with a joint, between 2 m and 4 m, set the percentage from 40 to 60;
- for booms between 6 m and 8 m, set the percentage from 60 to 70.
F38 Closing slow-down point 20 = 20% of travel /... / 75 = 75% of travel
Determining the starting point of closing slow-down, as a percentage of the total travel.
Warning! The percentage varies depending on the type of boom:
- for 2 m booms with a joint, set the speed percentage from 20 to 40;
- for 4 m booms, set the percentage from 40 to 60;
- for 6 m booms, set the percentage from 60 to 70;
- for 8 m booms, set the percentage from 65 to 75.
F49 Managing serial
connection
To enable paired, alternate or CRP operation.
F50 Save data
To save users and settings to the memory roll.
This function only appears if a memory roll has been inserted in the electronic board.
F51 Read data
To load data saved in the memory roll.
This function only appears if a memory roll has been inserted in the electronic board.
F52 Parameters transfer in
paired/alternate mode
To load parameters from the MASTER barrier to the SLAVE barrier.
This function only appears if function F 49 is set to PAIRED or ALTERNATE operation.
F56 Peripheral number
For systems with more than one automation device using a CRP (Came Remote Protocol) connection system, set an address between 1 and
225 for each panel.
F60 Sleep mode
To reduce the energy consumption in stand-by.
F61 Pre-fl ashing
After an opening or closing command is given, the fl ashing light connected to 10-E1 fl ashes before the barrier begins to move.
For information on adjusting the time, see function F 21.
F63 Change COM speed
Set the communication speed used in the CRP (Came Remote Protocol) connection system.
U 1 Enter a user
Enter up to a maximum of 25 users and associate each one with a function chosen from the available options. Use the transmitter or another
command device to do this (see ENTERING A USER WITH AN ASSOCIATED COMMAND).
U 2 Delete a user
Delete a single user (see DELETING A SINGLE USER).
U 3 Delete users
15 = Minimum speed / ... / 40 = Maximum speed
20 = 20% of travel (minimum) / ... / 40 = 40% of travel (maximum)
10 = maximum sensitivity / ... / 100 = minimum sensitivity(default)
10 = maximum sensitivity / ... / 100 = minimum sensitivity(default)
40 = 40% of travel / ... / 60 = 60% of travel
0 = Deactivated (default) / 1 = Paired / 2 = Alternate / 3 = CRP
0 = Deactivated (default) / 1 = Activated
0 = Deactivated (default) / 1 = Activated
0 = Deactivated (default) / 1 = Activated
1 ----> 225
0 = Deactivated (default) / 1 = Activated
0 = during opening and closing (default) / 1 = only during closing / 2 = only during opening
0=1200 Baud / 1=2400 / 2=4800 / 3=9600 / 4=14400 / 5=19200 / 6=38400 / 7=57600 / 8=115200 B
1 = step-by-step command (open-close) / 3 = open command / 4 = partial/pedestrian opening command (for
paired or alternate systems) / 5 = output B1-B2
0 = Deactivated / 1 = Delete all users