3. Le BIOS consigne cet événement dans le fichier journal des événements système
(SEL) du processeur de service, comme indiqué dans l'exemple de sortie de l'outil
IPMItool ci-dessous :
#
ipmitool -H 10.6.77.249 -U root -P changeme -I lanplus sel list
8 | 09/25/2007 | 03:22:03 | System Boot Initiated #0x02 | Initiated by warm
reset | Asserted
9 | 09/25/2007 | 03:22:03 | Processor #0x04 | Presence detected | Asserted
a | 09/25/2007 | 03:22:03 | OEM #0x12 |
b | 09/25/2007 | 03:22:03 | System Event #0x12 | Undetermined system hardware
failure | Asserted
c | OEM record e0 | 00000002000000000029000002
d | OEM record e0 | 00000004000000000000b00006
e | OEM record e0 | 00000048000000000011110322
f | OEM record e0 | 00000058000000000000030000
10 | OEM record e0 | 000100440000000000fefff000
11 | OEM record e0 | 00010048000000000000ff3efa
12 | OEM record e0 | 10ab0000000010000006040012
13 | OEM record e0 | 10ab0000001111002011110020
14 | OEM record e0 | 0018304c00f200002000020c0f
15 | OEM record e0 | 0019304c00f200004000020c0f
16 | OEM record e0 | 001a304c00f45aa10015080a13
17 | OEM record e0 | 001a3054000000000320004880
18 | OEM record e0 | 001b304c00f200001000020c0f
19 | OEM record e0 | 80000002000000000029000002
1a | OEM record e0 | 80000004000000000000b00006
1b | OEM record e0 | 80000048000000000011110322
1c | OEM record e0 | 80000058000000000000030000
1d | OEM record e0 | 800100440000000000fefff000
1e | OEM record e0 | 80010048000000000000ff3efa
1f | 25/09/07 | 03:22:06 | System Boot Initiated #0x03 | Initiated by warm
reset | Asserted
20 | 25/09/07 | 03:22:06 | Processor #0x04 | Presence detected | Asserted
21 | 25/09/07 | 03:22:15 | System Firmware Progress #0x01 | Memory
initialization | Asserted
22 | 25/09/07 | 03:22:16 | Memory | Uncorrectable ECC | Asserted | CPU 2 DIMM 0
23 | 25/09/07 | 03:22:16 | Memory | Uncorrectable ECC | Asserted | CPU 2 DIMM 1
24 | 25/09/07 | 03:22:16 | Memory | Memory Device Disabled | Asserted | CPU
2 DIMM 0
25 | 25/09/07 | 03:22:16 | Memory | Memory Device Disabled | Asserted | CPU
2 DIMM 1