Operating instructions
CONTENTS
1. Introduction.
2. Technical information.
3. Safety precautions.
4. Operation.
5. Maintenance.
1. INTRODUCTION
Dear customer,
In order to make a reliable operating of the
elevator tower TE-034 possible, we have
created this operating instruction.
Before use, you are required to read the
operating instructions.
Please note the technical data.
Our products are subjected to stringent test
prior to series production and are monitored
continously and closely during the
manufacturing process.
In order to maintain this guarantee of function
and safety, original parts of the manufacturer's
design must be used. The user forfeits all
rights to claim if parts other than those of the
manufacturer are used or modifies the product
in any other way.
We reserve the right to modify design and
performance without prior notice when
contacting us with queries or ordering
spare parts the model type, year of manu-
facture, and serial number are to be
quoted.
2. TECHNICAL INFORMATION
2.1 - Elevator tower TE-034
2.2 - Designed to lift loads vertically up to
different heights as support for sets of
illumination.
All manuals and user guides at all-guides.com
2.3 - Maximum load : 100 Kg.
2.4 - Minimum load : 25 Kg.
2.5 - Maximum height : 3,2 m.
2.6 - Minimum height : 1,26 m.
2.7 - Area of base : 1,53 x 1,53 m.
2.8 - Transport weight : 17,5 Kg.
2.9 - Construction material : Steel profiles DIN
2394.
2.10 - Two profiles telescopic system
operated by cable of steel and guided by
channelled steel pulleys with ball bearings.
2.11 - Winch : 500 Kg. of maximum load with
automatic brake to stop the load.
Certification CE and GS VBG 8.
2.12 - Cable : Steel DIN 3060. Quality180
Kg/mm
2.13 - Cable diameter : 4 mm.
2.14 - Fixing of the profiles to the height
desired by safety steel ST-37 catches.
2.15 - Legs with nonslip synthetic ruber
mounting plates.
2.16 - Support system (SA) fixation with safety
catch pawl.
2.17 - Antirust protection and zinc coated
finish.
3. SAFETY PRECAUTIONS
3.1 - Place the tower only in strong and
level surfaces.
3.2 - Check that the support system (SA) is
fixed by the safety catch pawl (R).