Broan ALLURE QS2 Série Mode D'emploi
Masquer les pouces Voir aussi pour ALLURE QS2 Série:

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

ALLURE
®
QS2 SERIES RANGE HOOD
READ AND SAVE THESE INSTRUCTIONS
!
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY
TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If
you have questions, contact the manufacturer at the address or
telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel
and lock the service disconnecting means to prevent power from
being switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a qualified
person(s) in accordance with all applicable codes and standards,
including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of
gases through the flue (chimney) of fuel burning equipment to
prevent backdrafting. Follow the heating equipment manufacturer's
guideline and safety standards such as those published by the
National Fire Protection Association (NFPA), and the American
Society of Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage electrical
wiring and other hidden utilities.
6. To reduce the risk of fire or electric shock, do not use this range
hood with an additional speed control device.
7. Ducted fans must always be vented to the outdoors.
8. To reduce the risk of fire, use only metal ductwork.
9. Use with approved cord-connection kit only.
10. This unit must be grounded.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
1. Never leave surface units unattended at high settings. Boilovers
cause smoking and greasy spillovers that may ignite. Heat oils
slowly on low or medium settings.
2. Always turn hood ON when cooking at high heat or when cooking
flaming foods.
3. Clean ventilating fans frequently. Grease should not be allowed to
accumulate on fan or filter.
4. Use proper pan size. Always use cookware appropriate for the size
of the surface element.
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT
OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:*
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal
tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS.
If the flames do not go out immediately, EVACUATE AND CALL
THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN — You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels - violent
steam explosion will result.
4. Use an extinguisher ONLY if:
A. You know you have a Class ABC extinguisher and you already
know how to operate it.
B. The fire is small and contained in the area where it started.
C. The fire department is being called.
D. You can fight the fire with your back to an exit.
* Based on "Kitchen Fire Safety Tips" published by NFPA.
FOR DOMESTIC COOKING ONLY
!
CAUTION
1. For indoor use only.
2. For general ventilating use only. Do not use to exhaust hazard-
ous or explosive materials and vapors.
3. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
4. For best capture of cooking impurities, your range hood should
be mounted so that the top of the hood is 24-30" above the
cooking surface.
5. Please read specification label on product for further information
and requirements.
Installer: Leave this manual with
the homeowner.
Homeowner: Operating and
Cleaning information on page 6.
NOTE
If hood is to be installed Non-Ducted:
Purchase a set of (2) non-ducted filters from your
local distributor or retailer and attach them to the
aluminum mesh filters.
TABLE OF CONTENTS
This manual is divided into sections as follows:
"PREPARE HOOD LOCATION"
Run ductwork from roof or wall cap, and electrical wiring from
service panel - to installation location
"PREPARE THE HOOD"
Get your hood ready for installation
"CONNECT WIRING"
Make electrical wiring connections to hood
"INSTALL HOOD"
Secure hood to cabinet and ductwork - install bulbs and filters
"OPERATION"
How to use the hood controls
"CLEANING"
Keep your hood in top working condition
"SERVICE PARTS"
Part numbers and exploded view of hood components
"WARRANTY"
One-year limited warranty and how to contact us
Register your product online at: www.broan.ca/register
ALLURE
QS2 SERIES
®
RANGE HOOD
Page 1
Patent No.:
US D450, 829 S
!

Publicité

Table des Matières
loading

Sommaire des Matières pour Broan ALLURE QS2 Série

  • Page 1 B. The fire is small and contained in the area where it started. C. The fire department is being called. D. You can fight the fire with your back to an exit. Register your product online at: www.broan.ca/register * Based on “Kitchen Fire Safety Tips” published by NFPA.
  • Page 2: Prepare The Hood

    ALLURE QS2 SERIES ® RANGE HOOD Page 2 PREPARE HOOD LOCATION PREPARE THE HOOD ROOF CAP FILTERS 3¼" X 10" (For vertical discharge) SOFFIT HOUSE WIRING CABINET (Top or Back of hood) WALL CAP Remove tape holding Filters in place. Pull down on filter HOOD HOOD tabs or finger holes and lift filters out.
  • Page 3 ALLURE QS2 SERIES ® RANGE HOOD Page 3 PREPARE THE HOOD PREPARE THE HOOD AIR CHUTE Remove Air Chute - held in place with one (1) screw. NOTE: Be care- ful not to discon- nect any wires. ELECTRICAL BAFFLE CABLE CLAMP Remove either top or back wiring knockout and install ap- Remove Baffle TABS...
  • Page 4 ALLURE QS2 SERIES ® RANGE HOOD Page 4 PREPARE THE HOOD PREPARE THE HOOD TIES SCREW BLOWER RETAINING WHEEL RING SMALL DIAMETER RING SECTIONS MOTOR STOP SLOTS EDGE Non-Ducted Installations Only: Require a Performance Ring to be attached to the blower wheel. To install ring: 1.
  • Page 5: Connect Wiring

    ALLURE QS2 SERIES ® RANGE HOOD Page 5 INSTALL HOOD CONNECT WIRING WARNING: To reduce the risk of electric shock, make sure power is switched off at the service panel. Lock or tag service panel to prevent power from being switched on accidentally. HOUSE WIRING (120 VAC)
  • Page 6 ALLURE QS2 SERIES ® RANGE HOOD Page 6 NON-DUCTED FILTERS CLEANING If hood is to be installed Non-Ducted: WARNING: To reduce the risk of electric shock, discon- nect from power supply before cleaning. Purchase a set of (2) Non-Ducted Filters from your local distributor or retailer and attach them to the aluminum mesh Aluminum mesh filters: Clean frequently using hot water and a filters.
  • Page 7: Service Parts

    ALLURE QS2 SERIES ® RANGE HOOD Page 7 SERVICE PARTS KEY NO. PART NO. DESCRIPTION R740013 Damper/Duct Connector (includes hardware) R602017 Screw, #8-18 x ¼ Hex* (2 in package) R334755 Motor Capacitor (includes wire nuts & hardware) R501031 Isolation Transformer R627501 Nameplate, White R627502...
  • Page 8 IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. During this one-year period, Broan-NuTone will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service.
  • Page 9 Vous avez appelé votre poste local de lutte contre notre service à la clientèle. les incendies. D. Vous pouvez combattre le feu tout en ayant accès à une sortie. Enregistrez votre produit en ligne à : www.fr.broan.ca/register * Basé sur “Kitchen Fire Safety Tips” édité par NFPA.
  • Page 10: Préparez L'emplacement

    HOTTE DE CUISINIÈRE DE LA SÉRIE ALLURE QS2 SERIES ® RANGE HOOD ALLURE ® Page 10 PRÉPAREZ L’EMPLACEMENT PRÉPAREZ LA HOTTE CAPUCHON DE TOIT CONDUIT DE 8, 3 CM X 25,4 CM FILTRES (Pour évacuation verticale) SOFFITE FIL DU PANNEAU D'ALIMENTATION ÉLECTRIQUE (Branché...
  • Page 11 HOTTE DE CUISINIÈRE DE LA SÉRIE ALLURE QS2 SERIES ® ALLURE RANGE HOOD ® Page 11 PRÉPAREZ LA HOTTE PRÉPAREZ LA HOTTE CHUTE D’ A IR Enlevez le chute d’air - main- tenue par une (1) vis. REMARQUE : Prendre garde de ne débranch- er aucun fil.
  • Page 12 HOTTE DE CUISINIÈRE DE LA SÉRIE ALLURE QS2 SERIES ® ALLURE ® RANGE HOOD Page 12 PRÉPAREZ LA HOTTE PRÉPAREZ LA HOTTE ATTACHES ROUE DU VENTILA- PATTE ANNEAU TEUR EXTRÉMITÉ DE COMPRESSION FAIBLE DIAMÈTRE ANNEAU SECTIONS FENTES DU MO- BORD TEUR LIMITE 10 Pour installations sans conduit seulement : Vous devez installer...
  • Page 13: Branchez Les Fils D'alimentation Élec- Trique

    HOTTE DE CUISINIÈRE DE LA SÉRIE ALLURE QS2 SERIES ® RANGE HOOD ALLURE ® Page 13 BRANCHEZ LES FILS INSTALLEZ LA HOTTE D’ALIMENTATION ÉLEC- TRIQUE AVERTISSEMENT: Afin de prévenir les risques d’électrocution, assurez-vous que le courant ait été interrompu au panneau d’alimentation principal. Ver- rouillez ce dernier ou apposez un indicateur voyant pour éviter que quelqu’un ne remette accidentellement le courant en marche.
  • Page 14: Fonctionnement

    HOTTE DE CUISINIÈRE DE LA SÉRIE ALLURE QS2 SERIES ® RANGE HOOD ALLURE ® Page 14 FILTRES SANS CONDUIT ENTRETIEN AVERTISSEMENT : Afin de prévenir les risques Si la hotte est installée sans conduit: d’électrocution, interrompez le courant avant de procéder Procurez-vous un ensemble de 2 filtres pour installation non ventilée à...
  • Page 15: Pièces De Remplacement

    HOTTE DE CUISINIÈRE DE LA SÉRIE ALLURE QS2 SERIES ® RANGE HOOD ALLURE ® Page 15 PIÈCES DE REMPLACEMENT NO. DU NO. DE SCHEMA PIECE DESCRIPTION R740013 Raccord du conduit avec le registre (avec vis d’assemblage) R602017 Vis # 8-18 x ¼ six pans* (2) R334755 Condensateur pour moteur (avec serre-fils et vis d’assemblage) R501031...
  • Page 16: Garantie

    GARANTIE LIMITÉE D’UN AN BROAN-NUTONE Broan-NuTone garantit à l’acheteur original que les produits vendus en vertu de la présente sont libres de tout vice de matériau ou de fabrication pour une période d’un an à compter de la date d’achat originale. CETTE GARANTIE NE COMPORTE AUCUNE AUTRE GARANTIE, EXPRESSE OU TACITE, Y COMPRIS, MAIS SANS S’Y LIMITER, LES GARANTIES TACITES DE VALEUR...