7) I/O Mapping Example
Example:
Assumed Settings
- Single Z-Boards
used with single solenoid
TM
valves
- Double Z-Boards
used with double solenoid
TM
valves
Discrete I/O Configuration
Pos
Module Type
Part No.
No.
1
MCM
239-1384
8O Sourcing
2
239-1315
(PNP)
16O Sourcing
3
239-1319
(PNP)
4I Sinking
4
239-1304
(NPN)
8I Sinking
5
239-1308
(NPN)
Manifold I/O Configuration
Outputs and Mapping Location
Valve Outputs = 12
Allocated Unused
Valve Outputs = 20
Discrete Outputs = 24
Total Outputs = 56
Inputs and Mapping Location
Byte 6; Bits 0-3,
Discrete Inputs = 12
Byte 7; Bits 0-7
Allocated and
Byte 6; Bits 4-7
Reserved Inputs = 4
Total Inputs = 16
G2-2 Series FIPIO Quick Start Manual
In
Out
Bytes
--
--
1
1
1
2
1
0
1
0
Byte 0; Bits 0-7
Byte 1; Bits 0-3
Byte 1; Bits 4-7
Bytes 2 - 3; Bits 0-7
Bytes 4,5 and 6;
Bits 0-7
3835058 TDG22FPQS2-0
Subject to change without notice
www.numatics.com/fieldbus
1/07
Page 6