13) Power Consumption and External Sizing Guide Chart
Power Consumption - Aux. Power Connector Pin for Valves and Outputs
Number of Solenoid Valve Coils Energized Simultaneously
Total load current drawn by simultaneously energized Discrete Outputs
with Discrete Outputs Power Jumper in "SP" Position (Factory Default).
Total load current drawn by Sensor Devices from Discrete Inputs source
Suggested External +24 VDC (Valves and Outputs) Fuse Value:
Power Consumption - Aux. Power Connector Pin for Node and Inputs
Total load current drawn by simultaneously energized Discrete Outputs
Total load current drawn by Sensor Devices from Discrete Inputs source
with Discrete Inputs Power Jumper in "UP" Position (Factory Default).
Number of Discrete I/O Status LEDs simultaneously on ___ X 0.015 A
Suggested External Pin +24 VDC (Node and Inputs) Fuse Value:
G2-2 Series FIPIO Quick Start Manual
Description
with Discrete Input Power Jumper in "SP" Position.
Description
Communication Node Power Consumption
with Discrete Outputs Power Jumper in "UP" Position.
Number of I/O modules installed ___ X 0.006 A
The standard power jumper configuration for all Output Modules is "SP".
The standard power jumper configuration for all Input Modules is "UP".
At any given moment in time, the combined current draw through +24VDC
(Valves & Outputs) pin and +24VDC (Node & Inputs) pin cannot exceed 8
amps. Therefore, the combined value of the external fuses on the two
+24VDC pins should not exceed 8 amps.
The internal fuses are installed to protect against fire damage due to
catastrophic failure of internal components. External fuses are
recommended for protection against power supply failure, over-current
conditions, etc...
3835058 TDG22FPQS2-0
Subject to change without notice
www.numatics.com/fieldbus
___ X 0.105 A (2012 and 2035
Series)
___ X 0.042 A (2005 Series)
Total:
Surge Compensation:
Total:
Surge Compensation:
1/07
Current
=
__________Amps
=
__________Amps
+
__________Amps
=
+
=
__________Amps
__________Amps
X
1.25
__________Amps
Current
=
.040 Amps
+
__________Amps
=
+
__________Amps
=
+
=
__________Amps
+
=
__________Amps
__________Amps
X
1.25
__________Amps
Page 12