6) Communication Module Rotary Switches
The Rotary switches allow the user to set the node address.
Rotary Switch Settings
Network Address:
Switch
NA 01 Sets the Ones Digits
NA 10 Sets the Tens Digits
Network Address Restrictions:
Node address 00 is reserved for the fieldbus control system (i.e. the PLC)
Node address 63 is reserved for configuration and diagnostic terminals
Node address 01-62 are used for connecting industrial peripheral devices to FIPIO
!
G2-2 Series FIPIO Quick Start Manual
Description
(i.e. Numatics FIPIO node)
Rotary switch settings do not take effect until power is cycled (turned
OFF and ON).