8344129
12. Line pressure should be increased to compensate for
unusually long air hoses (over 8 metres). The hose diameter
should be 3/8 in. l.D.
13. Air tool CFM consumption ratings are based upon a
25% duty cycle. If you require continuous duty, a larger
compressor will be required (eg. 4.0 CFM tool at continuous
duty requires 16.0 CFM to function at maximum torque).
LUBrication (air tooLS)
An automatic in-line
filter-regulator-
lubricator is
recommended as it
increases tool life
and keeps the tool in
sustained operation.
The in-line lubricator
should be regularly
checked and filled with
air tool oil.
Proper adjustment of
the in-line lubricator is
performed by placing
a sheet of paper next
to the exhaust ports
and holding the throttle
open approximately 30
seconds. The lubricator
is properly set when a
light stain of oil collects on the paper. Excessive amounts of oil
should be avoided.
In the event that it becomes necessary to store the tool for an
extended period of time (overnight, weekend, or longer), it should
receive a generous amount of lubrication at that time. The tool
should be run for approximately 30 seconds to ensure oil has
been evenly distributed throughout the tool. Store it in a clean and
dry environment.
Visit www.princessauto.com for more information
All manuals and user guides at all-guides.com
Reciprocating Air Saw
Tool
Valve
Quick
Coupler
Recommended Air Line Components
Male
Connector
Quick
Coupler
Oiler
Filter
Regulator with
Pressure Gauge
V 3.0
Male
Connector
Air Hose
on Reel
Air
Compressor
9