CHECKING THE DOSING SEAL
IMPORTANT ! Use no tool or metallic utensils
ADVICE: Before dismantling any part of the injection assembly it is advisable
to operate the DOSATRON, injecting clean water so as to rinse through the
injection system. In this way, risks of contact with concentrated solutions in
the injection assembly are minimized.
During any such intervention, wear protective eyewear and gloves !
METHOD OF REMOVING SEAL
Fig. 20 : Between finger and thumb, pinch the component and the seal ; push
towards one side to deform the seal.
Fig. 21 : Increase the deformation to grip the part of the seal thus exposed
and pull it out of its groove.
Clean the seal seating without any tools. Refitting is done by hand.
It is very important that the seal is not twisted once in place as this would
impair its efficiency.
Fig. 20
CLEANING AND RE-ASSEMBLING THE SUCTION VALVE SEAL
- Turn off the water supply and
allow the pressure to drop to zero.
- Unscrew the nut and pull
downwards to remove the suction
tube (Fig. 22).
- Unscrew and take off the suction
valve retaining nut (Fig. 23), pull
out the valve assembly, dismantle
the valve and thoroughly rinse the
separate components in clean
water.
- Put the valve components in the
order shown in the diagram (Fig.
24).
©
DOSATRON INTERNATIONAL S.A.S / 55
Fig. 21
%
%
5
5
Fig. 22
Fig. 23
%
5
Fig. 24