INSTALLATION
SAFETY
INSTALLATION
11. Safety
Only qualified contractors should carry out the maintenance and
repair of this appliance.
11.1 General safety information
We guarantee trouble-free operation and operational reliability
only if the original accessories and spare parts intended for the
appliance are used.
11.2 Instructions, standards and regulations
Note
Observe all applicable national and regional regulations
and instructions.
12. Appliance description
This appliance is a wall mounted electric direct heater. This ap-
pliance is particularly suitable for heating rooms, such as work
rooms, kitchens, bathrooms, wash rooms etc.
12.1 Standard delivery
- Wall mounting bracket
- Fixing bracket
13. Preparations
13.1 Minimum clearances
≥500
≥10
20
| CK 20, CKZ 20, CKR 20, CKT 20
≥100
≥100
14. Assembly
DANGER Electrocution
- If installing the appliance in rooms with a bath and/
or shower, take the relevant safety zone into ac-
count in accordance with the information on the ap-
pliance type plate.
- Install the appliance in such a way that switching
and control equipment cannot be touched by a per-
son in the bath or shower.
DANGER Fire
- Only fit the appliance to a vertical wall that is tem-
perature-resistant to at least 90 °C.
- Maintain minimum clearances to adjacent surfaces.
- Never install the appliance directly below a wall
socket.
f Check the hole distances for the wall mounting bracket in the
dimensioned drawing.
f Secure the wall mounting bracket with suitable fixing materi-
als. The horizontal and vertical slots in the wall mounting
bracket enable alignment if drilled holes are not completely
accurate.
f Hook in the appliance so that both top protrusions in the
back panel are inserted into the slots in the wall mounting
bracket.
f Secure the appliance with the fixing bracket and one screw
against unintentional unhooking. Hook the fixing bracket
from behind into the back panel.
15. Electrical connection
DANGER Electrocution
Carry out all electrical connection and installation work
in accordance with relevant regulations.
Damage to the appliance and environment
!
- Observe the type plate. The specified voltage must
match the mains voltage.
The cable must not touch the appliance.
Ensure the socket or junction box is at least 10 cm from the ap-
pliance.
Never install the appliance directly below a wall socket.
If a permanent connection is required, trim the cable (cut off the
plug) so that it is routed directly to the junction box.
In the case of a permanent connection, the appliance must be able
to be separated from the power supply by an isolator that discon-
nects all poles with at least 3 mm contact separation.
This appliance is unsuitable for fixed cables.
WWW.STIEBEL-ELTRON.COM