Maintenance And Service; Maintenance And Cleaning - CST/BERGER AL Serie Notice Originale

Masquer les pouces Voir aussi pour AL Serie:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 34
Troubleshooting
Corrective Measures
Cause
Measuring tool does not switch on or reacts
incorrectly
Batteries or battery pack
dead or defective
Batteries incorrectly
inserted (wrong polarity)
Battery contacts dam-
aged from leaky batteries/
rechargeable batteries
Battery contacts of bat-
tery lid and housing lack
contact
Safety strip in battery
compartment not or not
completely removed
before starting operation
for the first time
"ERROR/BATTERY LOW" indicated on the
display
Batteries or battery pack
dead
"ERROR/X TOO STEEP" or "ERROR/Y TOO
STEEP" indicated on the display
Measuring tool not within
the self-levelling range
Indication for exceeding the self-levelling
range is being displayed despite horizontal
set-up
Malfunction of the level-
ling procedure
"ERROR/GD TOO STEEP" indicated on the
display
The set grade angle can
not be reached
Measuring tool rotates but does not level in
Measuring tool without
automatic levelling while
in operation
2 610 A15 112 • 12.8.09
Causes and
Corrective Measure
Check batteries or battery
pack with battery tester
and replace as required,
or charge battery pack
Insert batteries correctly
Clean battery contacts
Readjust/realign battery
contacts; firmly tighten
nut 14 of the battery lid
Remove paper or paper
remainders between the
battery contacts
Replace batteries or
battery pack, or charge
battery pack
Position measuring tool
horizontally and switch on
again
Contact authorised serv-
ice agent for Bosch
power tools
Position measuring tool
horizontally and switch on
again
Switch on automatic lev-
elling
Cause
"ERROR/SPINDLE ERR" indicated on the
display
Spindle-motor error
Measuring tool reacts implausible after
pressing a button
When the corrective measures do not eliminate an
error, please contact an authorised service agent for
Bosch power tools.

Maintenance and Service

Maintenance and Cleaning

Note: The measuring tool can also be calibrated via
the "CAL" (calibration) menu. This calibration may
only be carried out through an authorised service
agent for Bosch power tools.
Store and transport the measuring tool only in the sup-
plied case.
Keep the measuring tool clean at all times.
Wipe off debris using a moist and soft cloth. Do not
use any cleaning agents or solvents.
Regularly clean the surfaces at the exit opening of the
laser in particular, and pay attention to any fluff of
fibres.
When heavily contaminated, the measuring tool can
be cleaned under running water. Do not immerse the
measuring tool in water and do not subject it to a high-
pressure water jet.
Note: Before storing, allow the measuring tool and the
case to dry completely. Otherwise, vapours can devel-
ope in the closed case due to residual moisture, lead-
ing to corrosion of the measuring tool's circuit board. In
this case, warranty claims shall be rendered void.
If the measuring tool should fail despite the care taken
in manufacturing and testing procedures, repair
should be carried out by an authorised after-sales
service centre for Bosch power tools. Do not open the
measuring tool yourself.
In all correspondence and spare parts orders, please
always include the 10-digit article number given on
the type plate of the measuring tool.
Corrective Measure
Contact authorised serv-
ice agent for Bosch
power tools
For a reset of the soft-
ware, remove battery lid
18 and then mount again
English | 29

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Algr

Table des Matières