2. Reserve a section of the drain pipe and power
cable for installation when binding. When you
have bound up to a certain point, separate the
indoor power cable and then the drain pipe.
Step nine: hang the indoor unit
1. Insert the bound pipes into the wall pipe and route them through the hole in the wall.
2. Hang the indoor unit on the wall-installation plate.
3. Fill the gap between the pipes and the hole in the wall with sealant.
4. Secure the wall pipe.
5. Check that the indoor unit is securely installed and flush against the wall.
interno
tubo a
parete
interno
esterno
tubo a parete
gomma di sigillatura
gancio superiore
gancio inferiore del telaio di montaggio a parete
N.B.
Avoid bending the drain pipe too much in order to prevent clogging.
Outdoor unit installation
For all connections refer to the wiring diagrams supplied with the unit. If the outdoor unit was connected
to a higher level than the one of the indoor unit, you must make a siphon. The outdoor unit must be
installed outdoors, in a perfectly horizontal position, respecting the minimum distances to allow the air
to flow and the execution of any maintenance. The unit is built with resistant materials to protect it from
any weather condition so it's not necessary to protect it in a particular way. Make sure however that
the heat exchanger is not exposed to the danger of hail. If you want to attach the unit to a wall, use
brackets appropriately sized to support the weight of the unit. Condensation produced due to the
operation in heating can be piped to a drain using the appropriate predisposition.
V 01/20
cavo di alimentazione
interno ed esterno
tubo del
liquido
fascetta
tubo di
scarico
indoor unit
indoor and outdoor power cable
gas pipe
binding tape
drain pipe
liquid pipe
esterno
gomma di
sigillatura
fascetta
cavo di alimentazione interno
3. Bind them evenly.
4. The liquid pipe and gas pipe must be bound
separately at the end.
N.B.:
The power cable and signal control cable must
not be rolled or coiled.
The
drain pipe must be bound at the bottom.
gancio inferiore del telaio
di montaggio a parete
indoors
outdoors
wall pipe
rubber sealant
upper hook
lower hook of wall installation frame
binding tape
Indoor powercable
gancio superiore