Step seven: connect the indoor unit electrical cable
1. Open the panel. Remove the screw that
secures the small panel covering the terminal
board.
2. Insert the indoor and outdoor unit connecting
cable into the rear hole corresponding to the
terminal block. Then pull it out of the front.
6. Remove the cable clip. Connect the power cable to the terminal block according to colour. Tighten
the screw and secure the power cable with the clip.
blu
nero
marrone
giallo verde
collegamento unità esterna
4. Reposition the terminal block cover and tighten the screws.
5. Close the panel.
N.B.:
• All wiring must be connected as shown on the unit's wiring diagram.
All indoor and outdoor unit cables must be connected by a qualified technician.
If the power cable is not long enough, contact the supplier for a new one. Do not attempt to extend
it yourself.
• For air conditioners equipped with a plug, the plug must be easily accessible upon completion of
installation.
• For air conditioners without a plug, install a circuit breaker on the line.
be single-pole and the contact gap must be greater than 3mm.
Step eight: bind the pipes
1. Bind together the connecting pipe, the power
cable and the drain pipe with binding tape.
V 01/20
pannello
coperchio cablaggio
foro di
passaggio
cavo
cavo di
alimentazione
pannello
vite
coperchio cablaggio
foro di passaggio
cavo
cavo di alimentazione
blue
black
brown
yellow green
Outdoor unit connection
tubo di collegamento
cavo di alimentazione interno
tubo di collegamento
tubo di scarico
vite
panel
screw
wiring cover
cable
through hole
power cable
The circuit breaker must
tubo di scarico
fascetta
connecting pipe
drain pipe
86