Definition Of Motor Connections; Magnetic Field Detection; Maintenance; Cleaning - BEHA UNITEST M-Indicator 9062 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Definition of Motor Connections

7.0 Definition of Motor Connections
"Connect conductors and alligator clamps to the
tester by respecting correct sequence (yellow to L1
/ green to L2 / red to L3)
"Connect the alligator clamps to the motor connec-
tions.
"Press button On (6). The green LED indicates that
the instrument is ready for testing.
"Turn the motor shaft by a half rotation towards the
right.
It is important to ensure that the user looks from the
front side onto the driving shaft.
"The red LED R (3) indicates clockwise motor rota-
tion if the lines are connected as follows: L1 to U,
L2 to V, L3 to W.
"The red LED L (4) indicates counter-clockwise
motor rotation if the lines are connected as follows:
L1 to V, L2 to U, L3 to W.

8.0 Magnetic field detection

" Laying out the UNITEST M-Indicator to a solenoid
valve. Taking care that the valve is in the proximity
of the sensor.
There is a magnetic field at the solenoid valve
aveilable when LED R (3) or LED L (4) shines.

9.0 Maintenance

When using Polaris Voltage and Continuity Testers in
compliance with the instruction manual, no particular
maintenance is required. If functional errors occur
during normal operating, our service department will
check your instrument without delay.
9.1

Cleaning

Prior to cleaning, remove voltage test from all meas-
urement circuits.If the instruments are dirty after daily
usage, it is adviseable clean them by using a damp
cloth and a mild household detergent.
Never use acid detergents or dissolvents for cleaning.
After cleaning, do not use the voltage tester for a pe-
riod of approx. 5 hours.
21

Publicité

Table des Matières
loading

Table des Matières