Transport Aid; Ventilation; General Balanced Flue Notes - HASE Luno Gas Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

2.4

Transport Aid

Fig. 5 Unscrew transport aid (a); Attention:
Rescrew the screws (b) into position in
the body of the stove,as they serve as the
level adjustment for the tile or soapstone
shelf cover
Fig. 6 For moving with a push-truck, place the
transport aid (a) into the upper slit in the
rear wall of the stove
Fig. 6 To lift the stove, place the transport aid
(a) into the lower slit in the rear of the
stove
2.5

Ventilation

Balanced Flue appliances can be installed
into a house without the need for additional
ventilation. They can also be installed into a
room that has a forced mechanical ventilation
and/or fume extraction without any special extra
requirements.
64
All manuals and user guides at all-guides.com
b
a
Fig. 5
a
Fig. 6
a
Fig. 7
2.6

General Balanced Flue Notes

There are many possibilities for installing this Concentric
Balanced Flue system into a building, both Roof and Wall terminations are possible, and
the fl ue can either be built into an existing chimney or a completely new fl ue system may
be constructed.
The system is based upon a Concentric Flue system which utilises an inner fl ue of 10 cm
diameter which passes through an outer fl ue of 15 cm diameter. The fl ue gasses that are the
products of combustion of the fi re, pass through the inner fl ue and are safely vented to the
outside environment. The gap between the inner and outer fl ues is the channel by which the
stove is supplied with air for combustion.
These concentric fl ues terminate outside of the property in a terminal, this terminal will keep
the expelled gasses and the fresh air for combustion separate. It is important that the terminal
is not blocked, a suitable guard maybe required if the terminal is located at a "Low" level
(usually when the terminal is within 2 m of fl oor level).
If an existing Flue or Chimney is to be utilised, then the installation engineer must be con-
sulted. If the chimney has been previously used it must be professionally cleaned and certi-
fi ed as being sound and fi t for use.
The European CE approval on this appliance is restricted to the Flue systems as specifi ed
by the supplier, thus the appliance must only be installed with the original fl ue system, no
others may be used.
Timber Frame Construction
Whilst it is possible to install room-sealed appliances in timber frame properties, great care
needs to be taken to ensure that the fl ue assembly does not interfere with the weather proo-
fi ng qualities of any outer wall which it may penetrate. Before attempting this work, further
details need to be referenced, (e.g. "Gas Installations in Timber Frame Buildings" from the
CORGI installer series in the UK).