Technical Data
Mains voltage / Frequency
Absorbed power
Type of protection / Insulation class
Suction fitting
Delivery fitting
Maximum flow rate
Maximum head
Maximum suction height including load losses
Power cable H05 RNF
Weight
Maximum dimension of pumped solid particles
Maximum admitted working pressure
Minimum ambient temperature
Maximum ambient temperature
Maximum temperature of the pumped fluid, in continuous mode 50° C
Maximum number of starts per hour, uniformly distributed
Sound power level (Lwa) *
Sound pressure level (Lpa)
Sound emission values obtained in conformity with the EN 12639 standard
* Measurement method according to EN ISO 3744
Ch. 3 Installation (see Fig. 1)
DANGER
Electric shock
risk
WARNING
DANGER
DANGER
Use a suction pump (2) with a diameter equivalent to that of the suction mouth of the electropump (1).
If the height (HA) is over 4 meters use a tube with a larger diameter. The suction line should be perfectly airtight. No
elbows and/or slopes should be present to prevent the formation of air locks that could affect the electropump
efficiency. A foot valve (3) with filter (4) should be fitted at about half a metre below the fluid that has to be pumped
(HI) on one end of the line. Load losses can be reduced using delivery piping with a diameter equivalent or greater than
the electropump mouth (5). It is advisable to install a check valve (6) directly on the delivery line to prevent the
electropump being damaged by "water hammer". A cut-off valve (7) should also be installed downstream from the
check valve, to facilitate maintenance operations. Piping should be fitted so that vibrations, when existing, tension and
weight do not affect the pump. Piping should be routed along the shortest and straighter track, avoiding an excessive
number of bends. Verify that the motor is properly ventilated. For permanent installations, it is advisable to fix the
electropump to the supporting base, connect the system with a section of non flexible pipe and insert a layer of rubber
(or another anti-vibration material) between the supporting base and the pump, in order to reduce vibrations.
The place of installation must be steady and dry to ensure proper and uninterrupted operation of the booster set.
ATTENTION!!!
Connection, suction and delivery pipes should be connected with the utmost care. Make sure that all
connections fixed by means of screws are sealed. Avoid applying excessive stress to tighten the screws of
6
The pump cannot be used for sea water and inflammable, corrosive, explosive or
dangerous liquids.
Verify that the electropump never runs without liquids.
When installing, please ensure electropump is disconnected from electrical
supply. Pumps in this series are not suitable for use in a swimming pool and
the relevant cleaning and servicing operations.
Protect the electropump and all pipes from bad weather or freezing conditions.
This appliance is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge, unless
they have been given supervision or instruction concerning use of the appliance by a
person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
To prevent possible injuries to people, avoid inserting hands into the mouth of the
pump if this is connected to the mains.
MULTIMAX 4 S
LOGIC-DROP
230 V ~ 50 Hz
800 Watt
IPX4 / F
33,25 mm (1"F)
33,25 mm (1"F)
5.000 l/h
45 m
7 m
1,5 m
8 Kg
≤ 2 mm
7 bar
5° C
40° C
40
74
66,5
2
GB
MULTIMAX 5 S
LOGIC-DROP
MULTIMAX 12K
230 V ~ 50 Hz
230 V ~ 50 Hz
1250 Watt
1800 Watt
IPX4 / F
IPX4 / F
33,25 mm (1"F) 41,90 mm (1"1/4 F)
33,25 mm (1"F) 41,90 mm (1"1/4 F)
6.600 l/h
12.000 l/h
60 m
46 m
7 m
8 m
1,5 m
1,5 m
11 Kg
21 Kg
≤ 2 mm
≤ 2 mm
7 bar
9 bar
5° C
5° C
40° C
40° C
50° C
50° C
40
40
79
/
70,5
/