12 Product information as per
Regulation (EU) No 813/
2013, Annex II, Table 2
Information requirements for heat pump space heaters and heat pump combination heaters
Model
Air-to-water heat pump
Water-to-water heat pump
Brine-to-water heat pump
Low-temperature heat pump
Equipped with a supplementary heater
Heat pump combination heater
Parameters shall be declared for medium-temperature application, except for low-temperature heat pumps. For low- temperature heat pumps, parameters
shall be declared for low-temperature application.
Parameters shall be declared for average climate conditions:
Item
Rated heat output (*)
Declared capacity for heating foer part load at indoor temperature 20°C and
outdoor temperature Tj
Tj = - 7°C
Tj = + 2°C
Tj = + 7°C
Tj = + 12°C
Tj = bivalent temperature
Tj = operation limit temperature
For air-to-water heat pumps
Tj = -15°C (if TOL < -20°C)
Bivalent temperature
Cycling interval capacity for heating
Degradation co-efficient (**)
Power consumption in modes other than active mode
Off mode
Thermostat-off mode
Standby mode
Crankcase heater mode
Other items
Capacity control
Sound power level, indoors/ outdoors
Emissions of nitrogen oxides
For heat pump combination heater:
Declared load profile
Daily electricity consumption
Contact details
(*) For heat pump space heaters and heat pump combination heaters, the rated output P rated is equal to the design load for heating Pdesignh , and the rated
heat output of a supplementary capacity for heating sup(Tj ).
(**) If Cdh is not determined by measurement nthen the default degradation is C dh = 0,9
(--) not applicable
EN-12
LA 6S-TUR
yes
no
no
no
no
no
Symbol
Value
Unit
Prated
4
kW
Pdh
3,6
kW
Pdh
4,9
kW
Pdh
6,1
kW
Pdh
6,9
kW
Pdh
3,3
kW
Pdh
3,3
kW
Pdh
2,6
kW
T
-10
°C
biv
-
kW
Pcych
Cdh
0,90
-
P
kW
0,015
OFF
P
kW
0,020
TO
P
kW
0,015
SB
P
kW
0,000
CK
fixed
L
-/56
dB
WA
NO
-
mg/kWh
x
-
Q
-
kWh
elec
Glen Dimplex Deutschland GmbH, Am Goldenen Feld 18, 95326 Kulmbach
452163.66.95 · FD 0107
Item
Seasonal space heating energy
efficiency
Declared coefficient of performance or primary energy ratio for part load at
indoor temperature 20 °C and outdoor temperature Tj
Tj = - 7°C
Tj = + 2°C
Tj = + 7°C
Tj = + 12°C
Tj = bivalent temperature
Tj = operation limit temperature
For air-to-water heat pumps:
Tj = -15°C (if TOL < -20°C)
For air-to-water heat pumps:
Operation limit temperature
Cycling interval efficiency
Heating water operating limit
temperature
Supplementary heater
Rated heat output (*)
Type of energy input
For air-to-water heat pumps: Rated
air flow rate, outdoors
For water-/brine-to-water heat
pumps: Rated brine or water flow
rate, outdoor heat exchanger
Water heating energy efficiency
Daily fuel consumption
LA 6S-TUR
Symbol
Value
Unit
111
%
s
COPd
1,88
-
COPd
2,77
-
COPd
3,69
-
COPd
4,45
-
COPd
1,65
-
COPd
1,65
-
COPd
1,26
-
TOL
-10
°C
-
-
COPcyc
WTOL
60
°C
Psup
0,89
kW
eletrical
m³ /h
-
2700
-
-
m³ /h
-
%
wh
Q
-
kWh
fuel
www.glendimplex.de