Product Information As Per Regulation (Eu) No 813/2013, Annex Ii, Table 2 - Dimplex LAK 3IMR Instructions D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

English
13 Product information as per
Regulation (EU) No 813/
2013, Annex II, Table 2
Information requirements for heat pump space heaters and heat pump combination heaters
Model
Air-to-water heat pump
Water-to-water heat pump
Brine-to-water heat pump
Low-temperature heat pump
Equipped with a supplementary heater
Heat pump combination heater
Parameters shall be declared for medium-temperature application, except for low-temperature heat pumps. For low- temperature heat pumps, parameters
shall be declared for low-temperature application.
Parameters shall be declared for average climate conditions:
Item
Rated heat output (*)
Declared capacity for heating foer part load at indoor temperature 20°C and
outdoor temperature Tj
Tj = - 7°C
Tj = + 2°C
Tj = + 7°C
Tj = + 12°C
Tj = bivalent temperature
Tj = operation limit temperature
For air-to-water heat pumps
Tj = -15°C (if TOL < -20°C)
Bivalent temperature
Cycling interval capacity for heating
Degradation co-efficient (**)
Power consumption in modes other than active mode
Off mode
Thermostat-off mode
Standby mode
Crankcase heater mode
Other items
Capacity control
Sound power level, indoors/ outdoors
Emissions of nitrogen oxides
For heat pump combination heater:
Declared load profile
Daily electricity consumption
Contact details
(*) For heat pump space heaters and heat pump combination heaters, the rated output Prated is equal to the design load for heating Pdesignh , and the rated
heat output of a supplementary capacity for heating sup(Tj ).
(**) If Cdh is not determined by measurement nthen the default degradation is Cdh = 0,9
(--) not applicable
EN-20
LAK 3IMR
yes
no
no
yes
yes
no
Symbol
Value
Unit
Prated
2
kW
Pdh
2,5
kW
Pdh
2,6
kW
Pdh
3,1
kW
Pdh
3,6
kW
Pdh
2,4
kW
Pdh
2,4
kW
Pdh
2,3
kW
T
-10
°C
biv
-
kW
Pcych
Cdh
0,90
-
P
kW
0,015
OFF
P
kW
0,020
TO
P
kW
0,015
SB
P
kW
0,000
CK
variable
L
42/60
dB
WA
NO
-
mg/kWh
x
-
Q
-
kWh
elec
Glen Dimplex Deutschland GmbH, Am Goldenen Feld 18, 95326 Kulmbach
452162.66.09 · FD 0007
Item
Seasonal space heating energy
efficiency
Declared coefficient of performance or primary energy ratio for part load at
indoor temperature 20 °C and outdoor temperature Tj
Tj = - 7°C
Tj = + 2°C
Tj = + 7°C
Tj = + 12°C
Tj = bivalent temperature
Tj = operation limit temperature
For air-to-water heat pumps:
Tj = -15°C (if TOL < -20°C)
For air-to-water heat pumps:
Operation limit temperature
Cycling interval efficiency
Heating water operating limit
temperature
Supplementary heater
Rated heat output (*)
Type of energy input
For air-to-water heat pumps: Rated
air flow rate, outdoors
For water-/brine-to-water heat
pumps: Rated brine or water flow
rate, outdoor heat exchanger
Water heating energy efficiency
Daily fuel consumption
LAK 3IMR - LAK 14ITR
Symbol
Value
Unit
η
134
%
s
COPd
2,60
-
COPd
3,35
-
COPd
5,28
-
COPd
5,25
-
COPd
2,39
-
COPd
2,39
-
COPd
2,05
-
TOL
-10
°C
-
-
COPcyc
WTOL
55
°C
Psup
0
kW
eletrical
m³ /h
-
3000
-
--
m³ /h
η
-
%
wh
Q
-
kWh
fuel
www.glendimplex.de

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Lak 6imrLak 9imrLak 14imrLak 14itr

Table des Matières