11. Technical Data
The Sendai, certified in compliance with DIN-EN 13240 and Art. 15 a B-VG (Aus-
tria), can only be operated when the fire box is closed. Conforms with the DIBt
(Deutschen Institut für Bautechnik/German Institute for Building Technology) ap-
proval criteria for direct vent fireplaces for solid fuels. Multiple connections to the
chimney are possible, see point 4. "Connection of Multiple Devices in Direct Vent
Operation". DIBt approval number: Z-43.12-396 / Typ FC41x und FC51x
The following data applies to the chimney characteristics in accordance with EN
13384-1 / 2
Combustion Values*
Nominal Thermal Output
Efficiency
Particulate
CO content at 13% O2
Waste Gas Mass Flow Rate
Waste Gas Outlet Temp.
Min. Supply Pressure at Nominal Thermal Output
Min. required combustion air volume
Depending on the insulation of the building, the nominal thermal output of 6 kW
indicated on 20 bis 80 m² (subject to change).
Dimensions:
Stove
133/175 - 220 cm
Fire box
Weight Sendai 135
Weight Sendai 175
(without heat retaining block )
Weight 1x heat retaining block flue pipe conection top / rear
46
All manuals and user guides at all-guides.com
Wood
83,5
Height
Width
37 cm
61 cm
21 cm
/ Additional module
¹Vertical flue pipe length Sendai 135 / 175
Diametro tubo di uscita fumi
Diametro tubo sistema di ventilazione Hase*
Front view Sendai 135:
6
kW
%
9
mg/m³
817
mg/m³
5,3
g/s
299
˚C
12
Pa
25
m³/h
Depth
40,5 cm
Top view Sendai 135:
27 cm
140 kg
163 / 15 kg
63 / 52,5 kg
Side view Sendai 135:
37
**For separate air supply in low-energy
houses and insufficient combustion
air supply in the room where the stove
is installed.
min. 25 cm
15 cm
10 cm
17,5
Inst. of Hase air system
below
Dimensions in cm