5.2.3
Function block
5.2.3.1 SlotIndex 2 (Valve 1)
Abs.
Length DB
Index
1
2
2
32
3
2
4
1
5
1
6
3
7
8
8
2
9
2
10
2
11-13 NU
14
2
15-16 NU
Table 16a: Function block Slotindex 2 Part 1
78
Type
N
ST_REV
S
S
S
S
N/S(RCAS)
D
D
DS34 D
DS34 D
DS34 D
Description
TAG_DESC
STRATEGY
ALERT_KEY
TARGET_MODE
MODE_BLK
ALARM_SUM (not yet in profile)
READ_BACK_D (cyclic possible)
SP_D, cyclic
Value Bit 0 (LSB)
Valve setting
OUT_D
Value Bit 0 (LSB)
Valve setting
not used
RCAS_IN_D (cyclic possible)
Value Bit 0 (LSB)
Valve setting
not used