6.1.3 Calibration
Each time the E680 board is powered, the integrated loop detector
performs a calibration of the connected loops. Therefore, you can
perform calibration by turning off power to the board for at least 10
seconds and then turning it back on.
From the barrier status display, you can press, at any time, SW4/CAL1
to calibrate the loop connected to the LOOP 1 input or SW5/CAL2 to
calibrate the loop connected to the LOOP2 input.
Calibration is highlighted by the board diagnostics by fl ashing LEDs
DL3 and DL4, and when calibration is completed, they will indicate
the loop detection status, if connected.
The other signals provided by the board diagnostics are described
in the following table:
LED Status
Off
On
Flashing (0.5 s)
Rapid flashing
Slow flashing
(5 s)
Two flashes (every 5 s) Non-conforming loop
2 2
4 5 6 7
2 2
If one or both magnetic loops are not installed, the loop
detector, following a fi rst attempt to calibrate, will keep
the status LEDs fl ashing every 5 seconds (as shown in
the above table).
Recommended loop inductivity range: 40-400 uH
6.2 Expert Confi guration
Wit the EXPERT configuration the operating logics previously programmed with Basic and Advanced configuration can be further customized.
Before making changes at this level, be certain that the steps you wish to change and their effect on the automated
system are fully understood.
After changing any of the third-level parameters the
To access EXPERT configuration, press F and, holding it, press + for approximately 10 seconds.
The use of F, + and - in this menu is the same as in the other two programming levels
"EXPERT" CONFIGURATION
Display.
Function
01
If this function is activated, automatic closing occurs after the pause time.
If this function is activated, two distinct input operation mode is obtained: OPEN for
02
opening and CLOSED for closing.
Activation of recognition of the OPEN and CLOSE input levels (maintained command).
That is to say, the board recognises the level (if, for example, with OPEN held, you press
03
STOP, when the latter is released, the automated system will continue to open). If
disabled the board commands a manoeuvre only if there is an input variation.
Activation of DEAD-MAN opening (command always pressed). Releasing the OPEN
04
command will stop operation
B680H
By adjusting the sensitivity of the loop detector, you determine the
variation of inductivity, for each channel, that a vehicle must cause in
order to activate the corresponding detector output.
Sensitivity is adjusted separately for each channel using the two
parameters
The loop must be laid at least 6" (15cm) from fixed metal objects, at
least 20" (50cm) from moving metal objects and no more than 2"
(5cm) from the surface of the final paving.
Use a standard AWG 16 unipolar cable (direct buried cable must have
double insulation). Make a preferably square or rectangular loop by
preparing a PVC cable duct or by tracing the paving, as shown in figure
16 (the corners must be cut at a 45° angle to avoid cable breaks). Lay
the cable using the number of windings shown in the table. The two
ends of the cable must be twisted together (at least 6 times per foot)
from the loop to the E680 board. Avoid splicing a cable (if necessary,
LOOP Status
solder the conductors and seal the splice using a heat-shrinking
tubing) and keep it separate from the mains power lines.
Loop clear
Loop engaged
Loop calibration
in progress
Loop short circuit
No loop
or loop interrupted
(resistance or induc-
tance values out of
range)
LO
parameter of the fi rst-level programming will show the value
10 sec
26
6.1.4 Adjusting sensitivity
S1
S2
and
in Basic confi guration
6.1.5 Making the loops
8 mm
Loop
Perimeter
less than 10 ft
from 10 to 13 ft
from 13 to 20 ft
from 20 to 40 ft
more than 40 ft
Y
no
Y
no
Y
no
03
is
Y
no
Nr.
of Windings
6
5
4
3
2
CU
Setting
= automatic closing
= disabled
= 2-input operation
= disabled
= level recognition
= status variation
recognition
= active
= disabled